Evidence map›Paper›PMID 30657163›Full record

SynthesisThe Cochrane database of systematic reviews2019

Laparoscopic entry techniques.

Gaity Ahmad, Jade Baker, John Finnerty, Kevin Phillips, Andrew Watson

Registry-linked trialAbstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06305975 (Blunt Fascial vs. Veress Needle Peritoneal Entry in Laparoscopic Gynecologic Surgery), which is not on this map. Cited by 60 papers, 4 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
60citing papers in PubMed, 4 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT06305975 naunknown statusnot on this mapstarted 2024, after this paper: background citation

Blunt Fascial vs. Veress Needle Peritoneal Entry in Laparoscopic Gynecologic Surgery: A Randomized Controlled Trial

TypeinterventionalSponsorCedars-Sinai Medical CenterRan2024 to 2025Enrolled100ConditionsLaparoscopic SurgeryArmsBlunt fascial abdominal entry, Veress needle abdominal entry
3 · Its place in the literature

Who cites it

60 citing papers in PubMed, 4 syntheses or guidelines pooled it.

  1. Pooled it
  2. Guideline
  3. Pooled it
  4. Pooled it
  5. Article
  6. Does prior cesarean section increase the risk of periumbilical adhesions in total laparoscopic hysterectomy?Wideochirurgia i inne techniki maloinwazyjne = Videosurgery and other miniinvasive techniques · 2026
    Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
  14. Review
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors.

Gaity AhmadDepartment of Obstetrics and Gynaecology, Pennine Acute Hospitals NHS Trust, Manchester, UK.
Jade Baker *
John Finnerty *
Kevin Phillips
Andrew Watson

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundLaparoscopy is a common procedure in many surgical specialties. Complications arising from laparoscopy are often related to initial entry into the abdomen. Life-threatening complications include injury to viscera (e.g. bowel, bladder) or to vasculature (e.g. major abdominal and anterior abdominal wall vessels). No clear consensus has been reached as to the optimal method of laparoscopic entry into the peritoneal cavity.

objectivesTo evaluate the benefits and risks of different laparoscopic entry techniques in gynaecological and non-gynaecological surgery. SEARCH

methodsWe searched the Cochrane Gynaecology and Fertility (CGF) Group trials register, CENTRAL, MEDLINE, Embase, PsycINFO, and trials registers in January 2018. We also checked the references of articles retrieved. SELECTION CRITERIA: We included randomised controlled trials (RCTs) that compared one laparoscopic entry technique versus another. Primary outcomes were major complications including mortality, vascular injury of major vessels and abdominal wall vessels, visceral injury of bladder or bowel, gas embolism, solid organ injury, and failed entry (inability to access the peritoneal cavity). Secondary outcomes were extraperitoneal insufflation, trocar site bleeding, trocar site infection, incisional hernia, omentum injury, and uterine bleeding. DATA COLLECTION AND ANALYSIS: Two review authors independently selected studies, assessed risk of bias, and extracted data. We expressed findings as Peto odds ratios (Peto ORs) with 95% confidence intervals (CIs). We assessed statistical heterogeneity using the I² statistic. We assessed the overall quality of evidence for the main comparisons using GRADE methods. MAIN

resultsThe review included 57 RCTs including four multi-arm trials, with a total of 9865 participants, and evaluated 25 different laparoscopic entry techniques. Most studies selected low-risk patients, and many studies excluded patients with high body mass index (BMI) and previous abdominal surgery. Researchers did not find evidence of differences in major vascular or visceral complications, as would be anticipated given that event rates were very low and sample sizes were far too small to identify plausible differences in rare but serious adverse events.Open-entry versus closed-entryTen RCTs investigating Veress needle entry reported vascular injury as an outcome. There was a total of 1086 participants and 10 events of vascular injury were reported. Four RCTs looking at open entry technique reported vascular injury as an outcome. There was a total of 376 participants and 0 events of vascular injury were reported. This was not a direct comparison. In the direct comparison of Veress needle and Open-entry technique, there was insufficient evidence to determine whether there was a difference in rates of vascular injury (Peto OR 0.14, 95% CI 0.00 to 6.82; 4 RCTs; n = 915; I² = N/A, very low-quality evidence). Evidence was insufficient to show whether there were differences between groups for visceral injury (Peto OR 0.61, 95% CI 0.06 to 6.08; 4 RCTs; n = 915: I² = 0%; very low-quality evidence), or failed entry (Peto OR 0.45, 95% CI 0.14 to 1.42; 3 RCTs; n = 865; I² = 63%; very low-quality evidence). Two studies reported mortality with no events in either group. No studies reported gas embolism or solid organ injury.Direct trocar versus Veress needle entryTrial results show a reduction in failed entry into the abdomen with the use of a direct trocar in comparison with Veress needle entry (OR 0.24, 95% CI 0.17 to 0.34; 8 RCTs; N = 3185; I² = 45%; moderate-quality evidence). Evidence was insufficient to show whether there were differences between groups in rates of vascular injury (Peto OR 0.59, 95% CI 0.18 to 1.96; 6 RCTs; n = 1603; I² = 75%; very low-quality evidence), visceral injury (Peto OR 2.02, 95% CI 0.21 to 19.42; 5 RCTs; n = 1519; I² = 25%; very low-quality evidence), or solid organ injury (Peto OR 0.58, 95% Cl 0.06 to 5.65; 3 RCTs; n = 1079; I² = 61%; very low-quality evidence). Four studies reported mortality with no events in either group. Two studies reported gas embolism, with no events in either group.Direct vision entry versus Veress needle entryEvidence was insufficient to show whether there were differences between groups in rates of vascular injury (Peto OR 0.39, 95% CI 0.05 to 2.85; 1 RCT; n = 186; very low-quality evidence) or visceral injury (Peto OR 0.15, 95% CI 0.01 to 2.34; 2 RCTs; n = 380; I² = N/A; very low-quality evidence). Trials did not report our other primary outcomes.Direct vision entry versus open entryEvidence was insufficient to show whether there were differences between groups in rates of visceral injury (Peto OR 0.13, 95% CI 0.00 to 6.50; 2 RCTs; n = 392; I² = N/A; very low-quality evidence), solid organ injury (Peto OR 6.16, 95% CI 0.12 to 316.67; 1 RCT; n = 60; very low-quality evidence), or failed entry (Peto OR 0.40, 95% CI 0.04 to 4.09; 1 RCT; n = 60; very low-quality evidence). Two studies reported vascular injury with no events in either arm. Trials did not report our other primary outcomes.Radially expanding (STEP) trocars versus non-expanding trocarsEvidence was insufficient to show whether there were differences between groups in rates of vascular injury (Peto OR 0.24, 95% Cl 0.05 to 1.21; 2 RCTs; n = 331; I² = 0%; very low-quality evidence), visceral injury (Peto OR 0.13, 95% CI 0.00 to 6.37; 2 RCTs; n = 331; very low-quality evidence), or solid organ injury (Peto OR 1.05, 95% CI 0.07 to 16.91; 1 RCT; n = 244; very low-quality evidence). Trials did not report our other primary outcomes.Other studies compared a wide variety of other laparoscopic entry techniques, but all evidence was of very low quality and evidence was insufficient to support the use of one technique over another. AUTHORS'

conclusionsOverall, evidence was insufficient to support the use of one laparoscopic entry technique over another. Researchers noted an advantage of direct trocar entry over Veress needle entry for failed entry. Most evidence was of very low quality; the main limitations were imprecision (due to small sample sizes and very low event rates) and risk of bias associated with poor reporting of study methods.

Indexed as

Abdominal WallIntraoperative ComplicationsBlood VesselsFemaleGynecologic Surgical ProceduresHumansIntestinesLaparoscopyMalePeritoneal CavityRandomized Controlled Trials as TopicUrinary Bladder

Identifiers

PMID30657163
PMCPMC6353066

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.