ArticleBiosensors2019
Textile-Based Potentiometric Electrochemical pH Sensor for Wearable Applications.
Article in Biosensors, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 36 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
36 citing papers in PubMed, 161 citations in OpenAlex.
- Recent advances of wearable electrochemical and optical sensors for sweat pH monitoring.RSC advances · 2026Review
- Smart and Sustainable: A Global Review of Smart Textiles, IoT Integration, and Human-Centric Design.Sensors (Basel, Switzerland) · 2025Review
- Development and Electrochemical Performance of a PANI-PA-PVA Hydrogel-Based Flexible pH Fiber Sensor for Real-Time Sweat Monitoring.Gels (Basel, Switzerland) · 2025Article
- Theoretical analysis of MWCNT and MXene/High-k pH BioFET sensors for biomedical applications.Scientific reports · 2025Article
- Wearable MXene-enhanced organic Bio-FET paper patch for glucose detection in sweat with pH and temperature calibration.Scientific reports · 2025Article
- An Embroidered Electrochemical Sensor to Measure Glucose Made with Commercially Available Textile Materials.Biosensors · 2025Article
- Beyond Flexible: Unveiling the Next Era of Flexible Electronic Systems.Advanced materials (Deerfield Beach, Fla.) · 2024Review
- Optimizing Carbon Structures in Laser-Induced Graphene Electrodes Using Design of Experiments for Enhanced Electrochemical Sensing Characteristics.ACS applied materials & interfaces · 2024Article
- Advanced Wearable Devices for Monitoring Sweat Biochemical Markers in Athletic Performance: A Comprehensive Review.Biosensors · 2024Review
- Toward an AI Era: Advances in Electronic Skins.Chemical reviews · 2024Review
- Bioreceptor modified electrochemical biosensors for the detection of life threating pathogenic bacteria: a review.RSC advances · 2024Review
- Sensors for Digital Transformation in Smart Forestry.Sensors (Basel, Switzerland) · 2024Article
- Nanostructured wearable electrochemical and biosensor towards healthcare management: a review.RSC advances · 2023Review
- Basic amino acid-mediated cationic amphiphilic surfaces for antimicrobial pH monitoring sensor with wound healing effects.Biomaterials research · 2023Article
- Wearable Sensors for Healthcare: Fabrication to Application.Sensors (Basel, Switzerland) · 2022Review
- Review
- Electronic textiles for energy, sensing, and communication.iScience · 2022Review
- Review
- Smart Electronic Textiles for Wearable Sensing and Display.Biosensors · 2022Review
- CuBiosensors · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
Abstract
In this work, we present a potentiometric pH sensor on textile substrate for wearable applications. The sensitive (thick film graphite composite) and reference electrodes (Ag/AgCl) are printed on cellulose-polyester blend cloth. An excellent adhesion between printed electrodes allow the textile-based sensor to be washed with a reliable pH response. The developed textile-based pH sensor works on the basis of electrochemical reaction, as observed through the potentiometric, cyclic voltammetry (100 mV/s) and electrochemical impedance spectroscopic (10 mHz to 1 MHz) analysis. The electrochemical double layer formation and the ionic exchanges of the sensitive electrode-pH solution interaction are observed through the electrochemical impedance spectroscopic analysis. Potentiometric analysis reveals that the fabricated textile-based sensor exhibits a sensitivity (slope factor) of 4 mV/pH with a response time of 5 s in the pH range 6⁻9. The presented sensor shows stable response with a potential of 47 ± 2 mV for long time (2000 s) even after it was washed in tap water. These results indicate that the sensor can be used for wearable applications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.