Evidence map›Paper›PMID 30654478›Full record

ArticleBiosensors2019

Textile-Based Potentiometric Electrochemical pH Sensor for Wearable Applications.

Libu Manjakkal, Wenting Dang, Nivasan Yogeswaran, Ravinder Dahiya

Open access · goldAbstract read
In one paragraph

Article in Biosensors, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 36 papers.

0numbers the graph read from it
0cells of the map it votes in
36citing papers in PubMed
10.0field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

36 citing papers in PubMed, 161 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Beyond Flexible: Unveiling the Next Era of Flexible Electronic Systems.Advanced materials (Deerfield Beach, Fla.) · 2024
    Review
  8. Article
  9. Review
  10. Review
  11. Review
  12. Sensors for Digital Transformation in Smart Forestry.Sensors (Basel, Switzerland) · 2024
    Article
  13. Review
  14. Article
  15. Review
  16. Review
  17. Review
  18. Review
  19. Review
  20. CuBiosensors · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Libu ManjakkalBendable Electronics and Sensing Technology Group, School of Engineering, University of Glasgow, Glasgow G128QQ, UK. Libu.Manjakkal@glasgow.ac.uk.
Wenting DangBendable Electronics and Sensing Technology Group, School of Engineering, University of Glasgow, Glasgow G128QQ, UK. w.dang.1@research.gla.ac.uk.ORCID 0000-0001-7066-1355
Nivasan YogeswaranBendable Electronics and Sensing Technology Group, School of Engineering, University of Glasgow, Glasgow G128QQ, UK. n.yogeswaran.1@research.gla.ac.uk.
Ravinder DahiyaBendable Electronics and Sensing Technology Group, School of Engineering, University of Glasgow, Glasgow G128QQ, UK. Ravinder.Dahiya@glasgow.ac.uk.ORCID 0000-0002-3858-3841
University of Glasgow · GB

Funding

RADIOBIOLOGY OF NORMAL TISSUESR01CA029644 · NCI · UNIVERSITY OF CALIFORNIA LOS ANGELES · PI WITHERS, H RODNEY · 1985 to 1988
–
Engineering and Physical Sciences Research Council EP/M002527/1Engineering and Physical Sciences Research Council EP/R029644/1Royal Academy of Engineering FoESFT5/100025/304218-01
6 · The paper itself

Abstract

In this work, we present a potentiometric pH sensor on textile substrate for wearable applications. The sensitive (thick film graphite composite) and reference electrodes (Ag/AgCl) are printed on cellulose-polyester blend cloth. An excellent adhesion between printed electrodes allow the textile-based sensor to be washed with a reliable pH response. The developed textile-based pH sensor works on the basis of electrochemical reaction, as observed through the potentiometric, cyclic voltammetry (100 mV/s) and electrochemical impedance spectroscopic (10 mHz to 1 MHz) analysis. The electrochemical double layer formation and the ionic exchanges of the sensitive electrode-pH solution interaction are observed through the electrochemical impedance spectroscopic analysis. Potentiometric analysis reveals that the fabricated textile-based sensor exhibits a sensitivity (slope factor) of 4 mV/pH with a response time of 5 s in the pH range 6⁻9. The presented sensor shows stable response with a potential of 47 ± 2 mV for long time (2000 s) even after it was washed in tap water. These results indicate that the sensor can be used for wearable applications.

Indexed as

Wearable Electronic DevicesBiosensing TechniquesDielectric SpectroscopyElectrodesGraphiteHydrogen-Ion ConcentrationPotentiometryTextilesGraphitee-textilegraphitepH sensorpotentiometricwearable system

Identifiers

PMID30654478
PMCPMC6468877
OpenAlexW2909217171

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.