Observational studyMedicine2019
A novel self-expanding biflanged metal stent vs tubular metal stent for EUS-guided transmural drainage of pancreatic pseudocyst: A retrospective, cohort study.
Observational study in Medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 13 citations in OpenAlex.
- Guidelines for endoscopic treatment of postinflammatory pancreatic and peripancreatic fluid collections. Recommendations of the Endoscopic Surgery Section of the Association of Polish Surgeons, the Endoscopy Section of the Polish Society of Gastroenterology, the Polish Pancreatic Club, the Laparoscopic and Robotic Surgery Section of the Association of Polish Surgeons, and the Pancreatic Surgery Section of the Association of Polish Surgeons; formulated by an expert panel led by Prof. Mateusz Jagielski, MD, PhD.Wideochirurgia i inne techniki maloinwazyjne = Videosurgery and other miniinvasive techniques · 2025Review
- Endoscopic ultrasound drainage of pancreatic fluid collections: do we know enough about the best approach?Therapeutic advances in gastroenterology · 2023Review
- Pancreatic pseudocyst: Dilemma of its recent management (Review).Experimental and therapeutic medicine · 2021Review
- A Comparison of Endoscopic Versus Surgical Creation of a Cystogastrostomy to Drain Pancreatic Pseudocysts and Walled-Off Pancreatic Necrosis in 5500 Patients.Annals of surgery open : perspectives of surgical history, education, and clinical approaches · 2020Article
- Burden of Liver Diseases: A Review from Iran.Middle East journal of digestive diseases · 2019Review
- Equivalent efficacy and safety of plastic stents and lumen-apposing metal stents in the treatment of peripancreatic fluid collections: a prospective cohort study.Annals of gastroenterologyArticle
- Endoscopic ultrasound-guided placement of lumen-apposing metal stent for transgastric drainage of loculated malignant ascites.Therapeutic advances in gastrointestinal endoscopyArticle
- EUS-guided cell transplantation: Planting seeds of hope.Endoscopic ultrasoundArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Although endoscopic ultrasound (EUS)-guided transmural drainage of pancreatic fluid collections with metal stents is generally preferred over plastic stents, its superiority among different types of metal stents has not yet been well studied. We conducted this study to compare clinical outcomes and complications of a novel self-expanding biflanged metal stent (BFMS) and a traditional-shaped tubular metal stent (TMS) in treating pancreatic pseudocyst (PPC).This was a retrospective analysis on consecutive patients with PPC underwent EUS-guided transmural drainage with either TMS or BFMS in a single tertiary center with expertise in management of complex biliary and pancreatic problems. The technical and functional success rate, reintervention, complications, and recurrence rate were evaluated.From September 2013 to January 2018, 125 patients (66.4% male, median age 47 years) underwent EUS-guided transmural drainage for PPC. Among them, 49 used TMS and 76 used BFMS. All patients met the inclusion criteria that cyst diameter was >6 cm or the distance between cyst and stomach wall was shorter than 1 cm. There was no difference in technical success (98% vs 97.4%, P = 1.0) or functional success rate (87.8% vs 92.1%, P = .54) using 2 types of metal stents. However, more procedure related complications occurred in TMS than in BFMS group. TMS group had a much higher migration rate than BFMS group (14.6% vs 0, P = .001), even though there was no significant difference in bleeding, infection, or death rate between 2 groups. With similar clinical outcomes, TMS group required more additional plastic stent placement than BFMS group for better drainage.TMS and BFMS placement can both be considered as methods of endoscopic transmural PPC drainage with equal efficacy, whereas BFMS could be preferred for fewer complications or less need of additional plastic stent placement.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.