ArticleMultidisciplinary respiratory medicine2019
Ultrasound evaluation of diaphragmatic mobility in patients with idiopathic lung fibrosis: a pilot study.
Article in Multidisciplinary respiratory medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06844331 (ULtrasOund Applicability in the Assessment of Patients With fibRosing Interstitial Lung Disease), which is not on this map. Cited by 18 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
ULtrasOund Applicability in the Assessment of Patients With fibRosing Interstitial Lung Disease (LORD): A Research Protocol of a Single Center, Real-life, Prospective Observational Study
Who cites it
18 citing papers in PubMed, 1 synthesis or guideline pooled it, 39 citations in OpenAlex.
- Mobility impact and methods of diaphragm monitoring in patients with chronic obstructive pulmonary disease: a systematic review.Clinics (Sao Paulo, Brazil) · 2020Pooled it
- Diaphragmatic Ultrasound in Fibrosing Interstitial Lung Disease: A Systematic Review of Current Evidence.Diagnostics (Basel, Switzerland) · 2026Review
- Article
- An ultrasound measurement method for assessing diaphragm mobility during maximal respiration.Scientific reports · 2025Article
- Correlation of diaphragmatic mobility and thickening assessed by lung ultrasound with severity of interstitial lung disease.Lung India : official organ of Indian Chest Society · 2024Article
- Ultrasound assessment of diaphragmatic dysfunction in non-critically ill patients: relevant indicators and update.Frontiers in medicine · 2024Review
- Ultrasound evaluation of diaphragmatic function in patients with idiopathic pulmonary fibrosis: a retrospective observational study.Respiratory research · 2023Observational
- Multiform-based Baduanjin exercise prevention and treatment for idiopathic pulmonary fibrosis: study protocol for a randomized controlled trial.BMC complementary medicine and therapies · 2023Article
- Diaphragmatic ultrasonography in patients with IPF: Is diaphragmatic structure and mobility related to fibrosis severity and pulmonary functional changes?Tuberkuloz ve toraks · 2023Article
- Differences in lung and lobe volumes between supine and upright computed tomography in patients with idiopathic lung fibrosis.Scientific reports · 2022Article
- Diaphragmatic thickness and excursion by lung ultrasound in pediatric chronic pulmonary diseases.Journal of ultrasound · 2022Article
- Diagnostic imaging in COVID-19 pneumonia: a literature review.Journal of ultrasound · 2021Review
- Not all abolished lung sliding are pneumothorax: the case of a particular lung atelectasis.Journal of ultrasound · 2021Article
- Does it make difference to measure diaphragm function with M mode (MM) or B mode (BM)?Journal of clinical monitoring and computing · 2020Article
- From an abdominal ultrasound to a lung disease passing through the diaphragm: a case of idiopathic pulmonary fibrosis.Journal of ultrasound · 2020Article
- Pelvic Floor Considerations in COVID-19.Journal of women's health physical therapy · 2020Article
- Thoracic ultrasound and SARS-COVID-19: a pictorial essay.Journal of ultrasound · 2020Article
- Diaphragmatic ultrasound: a review of its methodological aspects and clinical uses.Jornal brasileiro de pneumologia : publicacao oficial da Sociedade Brasileira de Pneumologia e TisilogiaReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundSome previous works have tested LUS use in diagnosing and monitoring interstitial lung diseases. B-lines are main sonographic signs for interstitial diseases. Increasing evidences suggest that dyspnea and impaired exercise capacity in IPF patients can be related, at least in part, to respiratory muscle dysfunction, in particular to diaphragm functionality. Both B-mode and M-mode ultrasound techniques have been employed to assess diaphragm excursion (DE), which measures the distance that the diaphragm is able to move during the respiratory cycle.
methodsThe main objective of this case-control study was to evaluate if differences exist between diaphragmatic excursions in IPF patients and in a control group of healthy subjects. Secondary objectives were to evaluate possible correlations among respiratory excursions, anthropometric parameters and respiratory function parameters. All patients performed spirometry and body plethysmography (PC). Diaphragm was examined by ultrasound imaging in B-MODE, and respiratory excursions were evaluated in M-MODE. Examination consisted of 3 measurements of the inspiratory phase at rest and after deep inspiration.
resultsTwelve patients with IPF and 12 healthy subjects were enrolled. There were no significant differences between respiratory excursions in patients and controls during spontaneous breathing, while there was a statistically significant difference between the mean values of the deep respiratory excursion in the two groups (
conclusionsDiaphragmatic mobility is lower in IPF patients than in healthy controls, especially during deep inspiration. The correlation between reduced FVC and diaphragmatic excursion values in IPF patients can be of interest, since it could represent an index of functional respiratory function performed by a non-invasive, low-cost, simple and reliable imaging technique, such as LUS.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials