Evidence map›Paper›PMID 30650590›Full record

ArticlePathogens (Basel, Switzerland)2019

Microbiological Air Quality in Heating, Ventilation and Air Conditioning Systems of Surgical and Intensive Care Areas: The Application of a Disinfection Procedure for Dehumidification Devices.

Michele Totaro, Anna Laura Costa, Beatrice Casini, Sara Profeti, Antonio Gallo, Lorenzo Frendo, Andrea Porretta, Paola Valentini, Gaetano Privitera, Angelo Baggiani

Abstract read
In one paragraph

Article in Pathogens (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Michele TotaroDepartment of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Via San Zeno 35-39, 56123 Pisa, Italy. micheleto@hotmail.it.
Anna Laura CostaDepartment of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Via San Zeno 35-39, 56123 Pisa, Italy. alauracosta@alice.it.
Beatrice CasiniDepartment of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Via San Zeno 35-39, 56123 Pisa, Italy. beatrice.casini@med.unipi.it.
Sara ProfetiDepartment of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Via San Zeno 35-39, 56123 Pisa, Italy. profeti.sara@gmail.com.
Antonio GalloDepartment of Public Health and Hygiene, Azienda USL Toscana Nord Ovest, 56100 Pisa, Italy. antonio.gallo@uslnordovest.toscana.it.
Lorenzo FrendoDepartment of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Via San Zeno 35-39, 56123 Pisa, Italy. lorenzo.frendo@hotmail.com.
Andrea PorrettaDepartment of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Via San Zeno 35-39, 56123 Pisa, Italy. andrea.porretta@med.unipi.it.
Paola ValentiniDepartment of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Via San Zeno 35-39, 56123 Pisa, Italy. paola.valentini@unipi.it.
Gaetano PriviteraDepartment of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Via San Zeno 35-39, 56123 Pisa, Italy. gaetano.privitera@med.unipi.it.
Angelo BaggianiDepartment of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Via San Zeno 35-39, 56123 Pisa, Italy. angelo.baggiani@med.unipi.it.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

International literature data report that the increase of infectious risk may be due to heating, ventilation and air conditioning (HVAC) systems contaminated by airborne pathogens. Moreover, the presence of complex rotating dehumidification wheels (RDWs) may complicate the cleaning and disinfection procedures of the HVAC systems. We evaluated the efficacy of a disinfection strategy applied to the RDW of two hospitals' HVAC systems. Hospitals have four RDW systems related to the surgical areas (SA1 and SA2) and to the intensive and sub-intensive care (IC and sIC) units. Microbiological air and surface analyses were performed in HVAC systems, before and after the disinfection treatment. Hydrogen peroxide (12%) with silver ions (10 mg/L) was aerosolized in all the air sampling points, located close to the RDW device. After the air disinfection procedure, reductions of total microbial counts at 22 °C and molds were achieved in SA2 and IC HVAC systems. An

Indexed as

air disinfectionAspergillus spp.HVAChydrogen peroxide

Identifiers

PMID30650590
PMCPMC6472009

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.