Evidence map›Paper›PMID 30649613›Full record

ArticleEuropean spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society2019

Material failure in dynamic spine implants: are the standardized implant tests before market launch sufficient?

Stavros Oikonomidis, Rolf Sobottke, Hans-Joachim Wilke, Christian Herren, Agnes Beckmann, Kourosh Zarghooni, Jan Siewe

Abstract read
PubMed Publisher
In one paragraph

Article in European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.2field-weighted citation impact, top 51% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 4 citations in OpenAlex.

  1. Review
  2. Review
  3. Review
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 1 country.

Stavros OikonomidisDepartment of Orthopedics and Trauma Surgery, Rhein-Maas Klinikum GmbH, Mauerfeldchen 25, 52146, Wuerselen, Germany. stavros.oikonomidis@uk-koeln.de.ORCID 0000-0002-7637-8611
Rolf SobottkeDepartment of Orthopedics and Trauma Surgery, Rhein-Maas Klinikum GmbH, Mauerfeldchen 25, 52146, Wuerselen, Germany.
Hans-Joachim WilkeInstitute of Orthopedic Research and Biomechanics, Center of Musculoskeletal Research, University of Ulm, Helmholtzstr. 14, 89081, Ulm, Germany.
Christian HerrenDepartment for Trauma and Reconstructive Surgery, University Hospital RWTH, Pauwelsstraße 30, 52074, Aachen, Germany.
Agnes BeckmannInstitute of General Mechanics, RWTH Aachen University, Templergraben 64, 52062, Aachen, Germany.
Kourosh ZarghooniFaculty of Medicine and University Hospital Cologne, Department of Orthopedics and Trauma Surgery, University of Cologne, Joseph-Stelzmann-Str. 24, 50931, Cologne, Germany.
Jan SieweFaculty of Medicine and University Hospital Cologne, Department of Orthopedics and Trauma Surgery, University of Cologne, Joseph-Stelzmann-Str. 24, 50931, Cologne, Germany.
University of Cologne · DERWTH Aachen University · DEKlinikum Bielefeld · DEUniversität Ulm · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeInternational Standards Organization (ISO) 12189 and American Society for Testing and Materials F2624 are two standard material specification and test methods for spinal implant devices. The aim of this study was to assess whether the existing and required tests before market launch are sufficient.

methodsIn three prospective studies, patients were treated due to degenerative disease of the lumbar spine or spondylolisthesis with lumbar interbody fusion and dynamic stabilization of the cranial adjacent level. The CD HORIZON BalanC rod and S

resultsA fatigue fracture of the material of the topping off system has been found in five cases (11%) for the group fitted with the CD HORIZON BalanC rod. In the group using the S

conclusionSpinal implants have to be checked by a notified body before market launch. The notified body verifies whether the implants fulfil the requirements of the current standards. These declared studies suggest that the current standards for the testing of load bearing capacity and stand ability of dynamic spine implants might be insufficient. Revised standards depicting sufficient deformation and load pattern have to be developed and counted as a requirement for the market launch of an implant. These slides can be retrieved under Electronic Supplementary Material.

Indexed as

Prostheses and ImplantsFemaleHumansLumbar VertebraeMaleMaterials TestingMiddle AgedProspective StudiesProsthesis FailureSpinal DiseasesSpinal FusionSpondylolisthesisWeight-BearingAdjacent segment diseaseDynamic spine implantsImplant testsMaterial failureTesting standards

Identifiers

PMID30649613
OpenAlexW2909582616

What OpenQuestion holds