Evidence map›Paper›PMID 30646622›Full record

ArticleMicromachines2019

Bacterial Concentration Detection using a PCB-based Contactless Conductivity Sensor.

Xiao-Yan Zhang, Zhe-Yu Li, Yu Zhang, Xiao-Qian Zang, Kosei Ueno, Hiroaki Misawa, Kai Sun

Open access · goldAbstract read
In one paragraph

Article in Micromachines, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.1field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 14 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 3 countries.

Xiao-Yan ZhangState Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin 150090, China. xyzhang774985529@163.com.
Zhe-Yu LiState Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin 150090, China. zhylee@hit.edu.cn.
Yu ZhangState Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin 150090, China. yuzhang429@126.com.
Xiao-Qian ZangState Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin 150090, China. 1112710105@hit.edu.cn.
Kosei UenoResearch Institute for Electronic Science, Hokkaido University, Sapporo 001-0021, Japan. k-ueno@es.hokudai.ac.jp.
Hiroaki MisawaResearch Institute for Electronic Science, Hokkaido University, Sapporo 001-0021, Japan. misawa@es.hokudai.ac.jp.
Kai SunState Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin 150090, China. ksun@hit.edu.cn.
Harbin Institute of Technology · CNHokkaido University · JP

Funding

National Natural Science Foundation of China 61674046State Key Laboratory of Urban Water Resource and Environment 2017TS04
6 · The paper itself

Abstract

Capacitively coupled contactless conductivity detection (C⁴D) is an improved approach to avoid the problems of labor-intensive, time-consuming and insufficient accuracy of plate count as well as the high-cost apparatus of flow cytometry (FCM) in bacterial counting. This article describes a novel electrode-integrated printed-circuit-board (PCB)-based C⁴D device, which supports the simple and safe exchange of capillaries and improves the sensitivity and repeatability of the contactless detection. Furthermore, no syringe pump is needed in the detection, it reduces the system size, and, more importantly, avoids the effect on the bacteria due to high pressure. The recovered bacteria after C⁴D detection at excitation of 25 Vpp and 60⁻120 kHz were analyzed by flow cytometry, and a survival rate higher than 96% was given. It was verified that C⁴D detection did not influence the bacterial viability. Moreover, bacteria concentrations from 10⁶ cells/mL to 10⁸ cells/mL were measured in a linear range, and relative standard deviation (RSD) is below 0.2%. In addition, the effects on bacteria and C⁴D from background solutions were discussed. In contrast to common methods used in most laboratories, this method may provide a simple solution to in situ detection of bacterial cultures.

Indexed as

bacterial concentrationcapacitively coupled contactless conductivity detection (C4D)capillaryE. coliprinted-circuit-board (PCB)

Identifiers

PMID30646622
PMCPMC6356519
OpenAlexW2908881991

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.