ArticleZhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery2019
[Imaging study on effect of femoral intramedullary guide on the alignment of femoral prosthesis in unicompartmental knee arthroplasty].
Article in Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 1 synthesis or guideline pooled it, 2 citations in OpenAlex.
- Does new instrument for Oxford unicompartmental knee arthroplasty improve short-term clinical outcome and component alignment? A meta-analysis.Journal of orthopaedic surgery and research · 2020Pooled it
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Objective: To explore the imaging features of intramedullary guide rod and its influence on the alignment of the femoral prosthesis in unicompartmental knee arthroplasty (UKA). Methods: Between August 2016 and November 2016, 50 patients (50 knees) with primary anteromedial osteoarthritis were treated with UKA by Oxford MicroPlasty minimally invasive replacement system. There were 10 males and 40 females. The age ranged from 62 to 77 years with an average of 68.8 years. Preoperative varus and flexion deformity angles were (5.22±3.46)° and (7.42±2.65)°, respectively. The knee range of motion (ROM) was (106.85±7.62)°. The Hospital for Special Surgery (HSS) score was 68.26±4.65. The angles between the femoral intramedullary guide rod and the anatomical axis of femur on the coronal and sagittal planes, the femoral component valgus/varus angle (FCVA), the femoral component posterior slope angle (FCPSA), knee varus deformity angle, and knee flexion deformity angle were measured by intra- and post-operative X-ray films. The postoperative ROM and HSS score were measured. Results: Intraoperative X-ray films measurement showed that the lateral side angles between femoral intramedullary guide rod and femoral anatomical axis were observed on coronal plane, and the angles ranged from 0.28 to 2.06° with an average of 0.96°. While the posterior side angles were observed on sagittal plane, and the angles ranged from 0.09 to 0.48° with an average of 0.23°. The angulations (>1°) between femoral intramedullary part guide rod and outside part of the rod were confirmed in 12 cases (24%) on coronal plane. Postoperative femoral prosthesis were mild varus in 38 patients (76%). The FCVA ranged from -1.76 to 4.08° with an average of 2.21°. The FCPSA ranged from 7.12 to 13.86° with an average of 9.16°. All patients were followed up 22-26 months, with an average of 24.5 months. The incisions healed by first intention. At last follow-up, the varus and flexion deformity angles were (1.82±1.05) and (2.54 ± 1.86)°, respectively. ROM was (124.62±5.85)° and HSS score was 91.58±3.65. There were significant differences between pre- and post-operative parameters ( Conclusion: UKA by Oxford MicroPlasty minimally invasive replacement system can obtain accurate femoral prosthesis position with the help of intramedullary guide system, and the effectiveness is excellent.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.