Evidence map›Paper›PMID 30643664›Full record

ArticleProceedings of the ... IEEE/RSJ International Conference on Intelligent Robots and Systems. IEEE/RSJ International Conference on Intelligent Robots and Systems2018

Analysis of Dynamic Response of an MRI-Guided Magnetically-Actuated Steerable Catheter System.

E Erdem Tuna, Taoming Liu, Russell C Jackson, Nate Lombard Poirot, Mac Russell, M Cenk Çavuşoğlu

Open access · greenAbstract read
In one paragraph

Article in Proceedings of the ... IEEE/RSJ International Conference on Intelligent Robots and Systems. IEEE/RSJ International Conference on Intelligent Robots and Systems, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
0.2field-weighted citation impact, top 45% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. A Master-Follower Teleoperation System for Robotic Catheterisation: Design, Characterisation and Tracking Control.The international journal of medical robotics + computer assisted surgery : MRCAS · 2025
    Article
  6. Article
  7. Article
  8. Contact Stability Analysis of Magnetically-Actuated Robotic Catheter Under Surface Motion.IEEE International Conference on Robotics and Automation : ICRA : [proceedings]. IEEE International Conference on Robotics and Automation
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

E Erdem TunaDepartment of Electrical Engineering and Computer Science, Case Western Reserve University, Cleveland, OH 44106, USA.
Taoming LiuDepartment of Electrical Engineering and Computer Science, Case Western Reserve University, Cleveland, OH 44106, USA.
Russell C JacksonDepartment of Electrical Engineering and Computer Science, Case Western Reserve University, Cleveland, OH 44106, USA.
Nate Lombard PoirotDepartment of Electrical Engineering and Computer Science, Case Western Reserve University, Cleveland, OH 44106, USA.
Mac RussellDepartment of Electrical Engineering and Computer Science, Case Western Reserve University, Cleveland, OH 44106, USA.
M Cenk ÇavuşoğluDepartment of Electrical Engineering and Computer Science, Case Western Reserve University, Cleveland, OH 44106, USA.
Case Western Reserve University · US

Funding

NRI: Small: Magnetic Resonance Imaging Guided Co-Robotic Active Catheter SystemR01EB018108 · NIBIB · CASE WESTERN RESERVE UNIVERSITY · PI CAVUSOGLU, M. CENK · 2013 to 2016
$1.3M
NIBIB NIH HHS R01 EB018108
6 · The paper itself

Abstract

This paper presents a free-space open-loop dynamic response analysis for an MRI-guided magnetically-actuated steerable intra-vascular catheter system. The catheter tip is embedded with a set of current carrying micro-coils. The catheter is directly actuated via the magnetic torques generated on these coils by the magnetic field of the magnetic resonance imaging (MRI) scanner. The relationship between the input current commands and catheter tip deflection angle presents an inherent nonlinearity in the proposed catheter system. The system nonlinearity is analyzed by utilizing a pendulum model. The pendulum model is used to describe the system nonlinearity and to perform an approximate input-output linearization. Then, a black-box system identification approach is performed for frequency response analysis of the linearized dynamics. The optimal estimated model is reduced by observing the modes and considering the Nyquist frequency of the camera system that is used to track the catheter motion. The reduced model is experimentally validated with 3

Identifiers

PMID30643664
PMCPMC6329396
OpenAlexW2910164053

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked