Evidence map›Paper›PMID 30635759›Full record

ArticleEuropean radiology2019

Radiation dose and image quality in intraoperative CT (iCT) angiography of the brain with stereotactic head frames.

Robert Forbrig, Lucas L Geyer, Robert Stahl, Jun Thorsteinsdottir, Christian Schichor, Friedrich-Wilhelm Kreth, Maximilian Patzig, Moriz Herzberg, Thomas Liebig, Franziska Dorn and 1 more

Abstract read
PubMed Publisher
In one paragraph

Article in European radiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Robert ForbrigInstitute of Neuroradiology, University Hospital, LMU Munich, Marchioninistrasse 15, 81377, Munich, Germany. robert.forbrig@med.uni-muenchen.de.ORCID http://orcid.org/0000-0002-1054-1463
Lucas L GeyerCenter of Radiology and Neuroradiology, Klinikum Ingolstadt, Ingolstadt, Germany.
Robert StahlDepartment of Radiology, University Hospital, LMU Munich, Munich, Germany.
Jun ThorsteinsdottirDepartment of Neurosurgery, University Hospital, LMU Munich, Munich, Germany.
Christian SchichorDepartment of Neurosurgery, University Hospital, LMU Munich, Munich, Germany.
Friedrich-Wilhelm KrethDepartment of Neurosurgery, University Hospital, LMU Munich, Munich, Germany.
Maximilian PatzigInstitute of Neuroradiology, University Hospital, LMU Munich, Marchioninistrasse 15, 81377, Munich, Germany.
Moriz HerzbergInstitute of Neuroradiology, University Hospital, LMU Munich, Marchioninistrasse 15, 81377, Munich, Germany.
Thomas LiebigInstitute of Neuroradiology, University Hospital, LMU Munich, Marchioninistrasse 15, 81377, Munich, Germany.
Franziska DornInstitute of Neuroradiology, University Hospital, LMU Munich, Marchioninistrasse 15, 81377, Munich, Germany.
Christoph G TrummInstitute for Diagnostic and Interventional Radiology, Neuroradiology and Nuclear Medicine, Städtisches Klinikum München Harlaching, Munich, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesIntraoperative CT (iCT) angiography of the brain with stereotactic frames is an integral part of navigated neurosurgery. Validated data regarding radiation dose and image quality in these special examinations are not available. We therefore investigated two iCT protocols in this IRB-approved study.

methodsRetrospective analysis of patients, who received a cerebral stereotactic iCT angiography on a 128 slice CT scanner between February 2016 and December 2017. In group A, automated tube current modulation (ATCM; reference value 410 mAs) and automated tube voltage selection (reference value 120 kV) were enabled, and only examinations with a selected voltage of 120 kV were included. In group B, fixed parameters were applied (300 mAs, 120 kV). Radiation dose was measured by assessing the volumetric CT dose index (CTDI

resultsTwo hundred patients (n = 100 in each group) were included. In group A, median selected tube current was 643 mAs (group B, 300 mAs; p < 0.001). Median values of CTDI

conclusionsATCM yielded disproportionally high radiation dose due to substantial tube current increase at the frame level, while image quality did not improve. Thus, ATCM should preferentially be disabled. KEY POINTS: • Automated tube current modulation (ATCM) yields disproportionally high radiation dose in intraoperative CT angiography of the brain with stereotactic head frames. • ATCM does not improve overall image quality in these special examinations. • ATCM is not yet optimised for CT angiography of the brain with major extracorporeal foreign materials within the scan range.

Indexed as

Imaging, Three-DimensionalAdolescentAdultAgedAged, 80 and overBrainBrain NeoplasmsCerebral AngiographyComputed Tomography AngiographyFemaleHumansMaleMiddle AgedNeurosurgical ProceduresRadiation DosageRetrospective StudiesBrainComputed tomography angiographyNeuronavigationRadiation dosage

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.