ArticleSensors (Basel, Switzerland)2019
Inner Profile Measurement for Pipes Using Penetration Testing.
Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Testing Concrete Sewer Maintenance Holes Using an Angular Modulated Penetrometer.Materials (Basel, Switzerland) · 2024Article
- Research on the 3D Reverse Time Migration Technique for Internal Defects Imaging and Sensor Settings of Pressure Pipelines.Sensors (Basel, Switzerland) · 2023Article
- Characterising Penetrometer Tip Contact during Concrete Condition Assessment.Sensors (Basel, Switzerland) · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
Penetration testing has been used to measure material properties for over fifty years. Currently, it is under-utilised as a contemporary scientific and engineering tool for investigating the condition of pipes whose inner surface has been exposed to chemical attack. We describe the design, development and calibration of a portable probe which uses a penetrative strain gauge load cell to measure where the semi-solid surface starts and stops within a pipe. We also describe the results of field tests of the probe in concrete sewers, affected by internal corrosion, where the probe proved to be a fast and reliable method for collecting pipe profile information. The results indicate significant benefit in the use of penetrometers to perform concrete sewer condition assessment.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.