ArticleBiomedical microdevices2019
Biaxial sensing suture breakage warning system for robotic surgery.
Article in Biomedical microdevices, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 1 synthesis or guideline pooled it, 23 citations in OpenAlex.
- The benefits of haptic feedback in robot assisted surgery and their moderators: a meta-analysis.Scientific reports · 2023Pooled it
- Optimizing arthroplasty outcomes: the impact of artificial intelligence and robotic assistance.Annals of medicine and surgery (2012) · 2026Review
- Artificial Intelligence in Thoracic Surgery: Transforming Diagnostics, Treatment, and Patient Outcomes.Diagnostics (Basel, Switzerland) · 2025Review
- Artificial intelligence in robot-assisted radical prostatectomy: where do we stand today?Journal of robotic surgery · 2024Review
- Artificial intelligence: revolutionizing robotic surgery: review.Annals of medicine and surgery (2012) · 2024Review
- Review
- An intelligent grasper to provide real-time force feedback to shorten the learning curve in laparoscopic training.BMC medical education · 2024Article
- Individualized Wound Closure-Mechanical Properties of Suture Materials.Journal of personalized medicine · 2022Article
- Artificial intelligence in thoracic surgery: a narrative review.Journal of thoracic disease · 2021Review
- Robotics and AI for Teleoperation, Tele-Assessment, and Tele-Training for Surgery in the Era of COVID-19: Existing Challenges, and Future Vision.Frontiers in robotics and AI · 2021Article
- Artificial intelligence and robotics: a combination that is changing the operating room.World journal of urology · 2020Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors at 2 institutions in 1 country.
Funding
Abstract
The number of procedures performed with robotic surgery may exceed one million globally in 2018. The continual lack of haptic feedback, however, forces surgeons to rely on visual cues in order to avoid breaking sutures due to excessive applied force. To mitigate this problem, the authors developed and validated a novel grasper-integrated system with biaxial shear sensing and haptic feedback to warn the operator prior to anticipated suture breakage. Furthermore, the design enables facile suture manipulation without a degradation in efficacy, as determined via measured tightness of resulting suture knots. Biaxial shear sensors were integrated with a da Vinci robotic surgical system. Novice subjects (n = 17) were instructed to tighten 10 knots, five times with the Haptic Feedback System (HFS) enabled, five times with the system disabled. Seven suture failures occurred in trials with HFS enabled while seventeen occurred in trials without feedback. The biaxial shear sensing system reduced the incidence of suture failure by 59% (p = 0.0371). It also resulted in 25% lower average applied force in comparison to trials without feedback (p = 0.00034), which is relevant because average force was observed to play a role in suture breakage (p = 0.03925). An observed 55% decrease in standard deviation of knot quality when using the HFS also indicates an improvement in consistency when using the feedback system. These results suggest this system may improve outcomes related to knot tying tasks in robotic surgery and reduce instances of suture failure while not degrading the quality of knots produced.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.