Evidence map›Paper›PMID 30629721›Full record

ArticlePloS one2019

Intra-arterial pulse wave analysis during thrombectomy for the assessment of collateral status - A feasibility study.

Johanna Sandmann, Thorsten Sichtermann, Franziska Sonja Müschenich, Hadi Nasri, Sarah Heringer, Anastasios Mpotsaris, Martin Kramer, Martin Wiesmann, Omid Nikoubashman

Abstract read
In one paragraph

Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Johanna SandmannDepartment of Diagnostic and Interventional Neuroradiology, University Hospital, RWTH Aachen University, Aachen, Germany.ORCID 0000-0001-6652-7655
Thorsten SichtermannDepartment of Diagnostic and Interventional Neuroradiology, University Hospital, RWTH Aachen University, Aachen, Germany.
Franziska Sonja MüschenichDepartment of Diagnostic and Interventional Neuroradiology, University Hospital, RWTH Aachen University, Aachen, Germany.
Hadi NasriDepartment of Diagnostic and Interventional Neuroradiology, University Hospital, RWTH Aachen University, Aachen, Germany.
Sarah HeringerDepartment of Diagnostic and Interventional Neuroradiology, University Hospital, RWTH Aachen University, Aachen, Germany.
Anastasios MpotsarisDepartment of Diagnostic and Interventional Neuroradiology, University Hospital, RWTH Aachen University, Aachen, Germany.
Martin KramerDepartment of Veterinary Clinical Sciences, Small Animal Clinic, Justus-Liebig-University, Gießen, Germany.
Martin WiesmannDepartment of Diagnostic and Interventional Neuroradiology, University Hospital, RWTH Aachen University, Aachen, Germany.
Omid NikoubashmanDepartment of Diagnostic and Interventional Neuroradiology, University Hospital, RWTH Aachen University, Aachen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeKnowledge of the collateralization of an occluded vessel is important for the risk-benefit analysis of difficult revascularization maneuvers during mechanical thrombectomy. If the territory behind a clot is well perfused, one could desist from performing a risky thrombectomy maneuver. The arterial pulse pressure curve may serve as an indicator for the collateralization of an occluded target vessel. We investigated the feasibility of arterial pulse measurements with a standard microcatheter.

methodsWe measured the intra-arterial blood pressure proximal and distal to the clot in 40 thrombectomy maneuvers in a porcine stroke model. We used a microcatheter (Trevo Pro 18, Stryker, Kalamazoo, CA, USA), a pressure transducer (MEMSCAP SP844), an AdInstruments Powerlab 16/35 workstation, and LabChart 8 Software (AdInstruments, Dunedin, New Zealand).

resultsMedian arterial blood pressure proximal and distal to the clot was 96.0 mmHg (IQR, 23.8 mmHg) and 47.5 mmHg (IQR, 43.5 mmHg), respectively (p < .001). The median difference between systolic maximum and diastolic minimum proximal and distal to the clot decreased significantly from 1.8 mmHg (IQR, 3.6 mmHg) to 0.0 mmHg (IQR, 0.5 mmHg) (p < .001). There was loss of the curve in 26 of 40 cases and loss of pressure in 23 of 40 cases (p = .008). There was no significant correlation between vessel diameter and either loss of the pulse pressure curve (p = .20) or overall pressure loss (p = .31).

conclusionIt is possible to measure the pulse pressure proximal and distal to the clot with a standard microcatheter used during mechanical thrombectomy.

Indexed as

Arterial PressureAnimalsBlood PressureBlood Pressure DeterminationCathetersFeasibility StudiesFemalePulse Wave AnalysisSwineThrombectomy

Identifiers

PMID30629721
PMCPMC6328207

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.