Evidence map›Paper›PMID 30629618›Full record

ArticlePloS one2019

Computational and experimental evaluation of the Tic-Tac-Toe RF coil for 7 Tesla MRI.

Narayanan Krishnamurthy, Tales Santini, Sossena Wood, Junghwan Kim, Tiejun Zhao, Howard J Aizenstein, Tamer S Ibrahim

Abstract read
In one paragraph

Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 29 papers.

0numbers the graph read from it
0cells of the map it votes in
29citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

29 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Measuring arterial tortuosity in the cerebrovascular system using Time-of-Flight MRI.medRxiv : the preprint server for health sciences · 2024
    Article
  14. Leveraging ultra-high field (7T) MRI in psychiatric research.Neuropsychopharmacology : official publication of the American College of Neuropsychopharmacology · 2024
    Review
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Narayanan KrishnamurthyUniversity of Pittsburgh, Department of Bioengineering, Pittsburgh, PA, United States of America.
Tales SantiniUniversity of Pittsburgh, Department of Bioengineering, Pittsburgh, PA, United States of America.
Sossena WoodUniversity of Pittsburgh, Department of Bioengineering, Pittsburgh, PA, United States of America.
Junghwan KimUniversity of Pittsburgh, Department of Bioengineering, Pittsburgh, PA, United States of America.
Tiejun ZhaoSiemens Medical Solutions, New York, NY, United States of America.
Howard J AizensteinUniversity of Pittsburgh, Department of Bioengineering, Pittsburgh, PA, United States of America.
Tamer S IbrahimUniversity of Pittsburgh, Department of Bioengineering, Pittsburgh, PA, United States of America.ORCID 0000-0001-6738-5855

Funding

High Performance Imaging for Assessment of Small Vessel Disease in Older Adults with DepressionR01MH111265 · NIMH · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI AIZENSTEIN, HOWARD J, IBRAHIM, TAMER S · 2016 to 2020
$3.6M
Subject-Insensitive and SNR Enhancing RF Arrays for High Field Parallel Human MRIR01EB009848 · NIBIB · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI IBRAHIM, TAMER S · 2009 to 2012
$1.3M
NIBIB NIH HHS R01 EB009848NIMH NIH HHS R01 MH111265
6 · The paper itself

Abstract

A variety of 7 Tesla RF coil systems have been proposed to produce spin excitation (B1+ field) and MR image acquisition. Different groups have attempted to mitigate the challenges at high and ultra-high field MRI by proposing novel hardware and software solutions to obtain uniformly high spin excitation at acceptable RF absorption levels. In this study, we extensively compare the designs of two distributed-circuit based RF coils: the Tic-Tac-Toe (TTT) head coil and TEM head coil on multiple anatomically detailed head models and in-vivo. Bench measurements of s-parameters and experimental B1+ field distribution were obtained in volunteers and compared with numerical simulations. RF absorption, quantified by both average and peak SAR, and B1+ field intensity and homogeneity, calculated/measured in terms of maximum over minimum and coefficient of variation (CV) in the region of interest (ROI), are presented for both coils. A study of the RF consistency of both coils across multiple head models for different RF excitation strategies is also presented.

Indexed as

Computer SimulationEquipment DesignEquipment Failure AnalysisHeadHumansImage EnhancementMagnetic Resonance ImagingPhantoms, ImagingRadio WavesSoftware

Identifiers

PMID30629618
PMCPMC6328242

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.