ArticleCureus2018
Whole Breast Irradiation with Halcyon™ 2.0: Workflow and Efficiency of Field-in-Field Treatment with Dynamic Beam Flattening Technique and kV Cone Beam Computed Tomography.
Article in Cureus, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Automated treatment planning for whole breast irradiation with individualized tangential IMRT fields.Journal of applied clinical medical physics · 2024Article
- Independent monitor unit verification for dynamic flattened beam plans on the Halcyon linac.Journal of applied clinical medical physics · 2023Article
- Comparison of sliding window and field-in-field techniques for tangential whole breast irradiation using the Halcyon and Synergy Agility systems.Radiation oncology (London, England) · 2021Article
- Per-fraction positional and dosimetric performance of prone breast tangential radiotherapy on Halcyon™ linear accelerator assessed with daily rapid kilo-voltage cone beam computed tomography: a single-institution pilot study.Radiation oncology (London, England) · 2020Article
- Article
- Increase in Superficial Dose in Whole-Breast Irradiation With Halcyon Straight-Through Linac Compared With Traditional C-arm Linac With Flattening Filter: In vivo Dosimetry and Planning Study.Advances in radiation oncologyArticle
- Dosimetric Characterization of the Dual Layer MLC System for an O-Ring Linear Accelerator.Technology in cancer research & treatmentArticle
- Initial Clinical Experience Treating Patients with Breast Cancer on a 6-MV Flattening-Filter-Free O-Ring Linear Accelerator.Advances in radiation oncologyArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Whole breast irradiation accounts for a substantial fraction of patients treated in Radiation Oncology clinics. The recently introduced Halcyon™ platform provided a high-throughput, simplified workflow. The 2.0 version introduced new features such as the dynamic beam flattening (DBF) technique that uses the upper layer of the multi-leaf collimator (MLC) to create a flat beam profile at depth and an improved kV cone beam computed tomography (kV CBCT). In this case report, we described our experience in whole breast irradiation with Halcyon 2.0 new features. The patient was simulated in the supine position with the same immobilization technique used on C-arm linacs and an additional contralateral elbow position measurement to ensure clearance. The treatment planning process using DBF and field-in-field technique was similar to the traditional flattened beam planning and did not require additional training. Dosimetric analysis showed satisfactory dose-volume histogram (DVH) parameters that met all the planning objectives, with maximal dose at 107% and V105% at 3.6% of the breast volume. Daily image-guided radiation therapy (IGRT) using improved CBCT showed excellent soft tissue contrasts and sufficient field of view. The average imaging and treatment time was nine minutes, and the average in-room time was 16.2 minutes. These treatment times were substantially higher than those for breast treatments on our Halcyon platform using an irregular surface compensator technique. The use of DBF contributed to the majority of treatment time increase due to the motion of the upper layer of the MLC to create a flat beam profile. The total treatment time using DBF might be too long for patients with deep inhalation breast hold (DIBH) and can be drastically reduced using an irregular surface compensator technique, also known as the electronic tissue compensation (ECOMP) technique, instead of the DBF-enabled field-in-field technique.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.