ArticleKorean journal of radiology2019
Fat Quantification in the Vertebral Body: Comparison of Modified Dixon Technique with Single-Voxel Magnetic Resonance Spectroscopy.
Article in Korean journal of radiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
20 citing papers in PubMed, 1 synthesis or guideline pooled it, 42 citations in OpenAlex.
- Association of proton-density fat fraction with osteoporosis: a systematic review and meta-analysis.Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA · 2024Pooled it
- Correlation of whole-body fat content and its distribution with lumbar fat content under different age, gender and BMI conditions: quantitative analysis of MRI based on deep learning.BMC musculoskeletal disorders · 2026Article
- Sex-specific patterns of skeletal muscle aging at the L3 level: a quantitative study based on opportunistic CT.BMC musculoskeletal disorders · 2026Article
- Biochemical and microenvironmental characterization of the disc-vertebra complex in non-specific low back pain using non-fat-saturation multi-slice CEST MRI.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026Article
- Added value of multiparametric MRI for diagnosing subcentimeter functional adrenal nodules in primary aldosteronism using CXCR4-targeted PET/MRI.European journal of nuclear medicine and molecular imaging · 2025Article
- Leveraging dixon-based magnetic resonance imaging for pelvic bone marrow imaging in radiotherapy.Physics and imaging in radiation oncology · 2025Article
- Paraspinal muscles and gluteus medius fat infiltration are both associated with lumbar disc herniation.Insights into imaging · 2025Article
- Fat Fraction and Iron Concentration in Lumbar Vertebral Bone Marrow in the UK Biobank.Obesity science & practice · 2025Article
- A three-material model for dual-layer detector spectral computed tomography measurements of marrow adipose tissue and bone mineral density.JBMR plus · 2025Article
- Exploring Fat Fraction and Vertebral Bone Quality Score in Lumbar Spine Magnetic Resonance Imaging: A Cross-Sectional Study on Associations and Clinical Implication.Diagnostics (Basel, Switzerland) · 2025Article
- Comparison of the zonal distribution of calcium salt density and fat marrow in bone-healthy and osteoporotic sacra: an image data analysis using quantitative computed tomography and magnetic resonance imaging.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2024Article
- Use of two-point and six-point Dixon MRI for fat fraction analysis in the lumbar vertebral bodies and paraspinal muscles in healthy dogs: comparison with magnetic resonance spectroscopy.Frontiers in veterinary science · 2024Article
- [Imaging Findings of Spinal Metastases with Differential Diagnosis: Focusing on Solitary Spinal Lesion in Older Patients].Journal of the Korean Society of Radiology · 2024Review
- Fat quantification of the rotator cuff muscles using CT histogram analysis in comparison with Dixon MRI sequence.The British journal of radiology · 2023Article
- Quantitative analysis of vertebral fat fraction and R2BMC musculoskeletal disorders · 2023Article
- Preliminary study for prediction of benign vertebral compression fracture age by quantitative water fraction using modified Dixon sequences: an imaging biomarker of fracture age.La Radiologia medica · 2023Article
- T2*-corrected Q-Dixon and reduced-FOV diffusion kurtosis imaging (DKI) parameters: correlation with QCT-derived bone mineral density (BMD) and ability to identify abnormal BMD and osteoporosis in postmenopausal women.Quantitative imaging in medicine and surgery · 2023Article
- Advances in Bone Marrow Imaging: Strengths and Limitations from a Clinical Perspective.Seminars in musculoskeletal radiology · 2023Article
- Use of proton density fat fraction MRI to predict the radiographic progression of osteoporotic vertebral compression fracture.European radiology · 2021Article
- Automatic Vertebral Body Segmentation Based on Deep Learning of Dixon Images for Bone Marrow Fat Fraction Quantification.Frontiers in endocrinology · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Objective: To compare the lumbar vertebral bone marrow fat-signal fractions obtained from six-echo modified Dixon sequence (6-echo m-Dixon) with those from single-voxel magnetic resonance spectroscopy (MRS) in patients with low back pain. Materials and Methods: Vertebral bone marrow fat-signal fractions were quantified by 6-echo m-Dixon (repetition time [TR] = 7.2 ms, echo time (TE) = 1.21 ms, echo spacing = 1.1 ms, total imaging time = 50 seconds) and single-voxel MRS measurements in 25 targets (23 normal bone marrows, two focal lesions) from 24 patients. The point-resolved spectroscopy sequence was used for localized single-voxel MRS (TR = 3000 ms, TE = 35 ms, total scan time = 1 minute 42 seconds). A 2 × 2 × 1.5 cm Results: There was a strong correlation between m-Dixon and MRS-based fat-signal fractions (slope = 0.86, R Conclusion: Given its excellent agreement with single-voxel-MRS, 6-echo m-Dixon can be used for visual and quantitative evaluation of vertebral bone marrow fat in daily practice.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.