Evidence map›Paper›PMID 30625455›Full record

ArticlePhysics in medicine and biology2019

Partial fourier shells trajectory for non-cartesian MRI.

Shengzhen Tao, Yunhong Shu, Joshua D Trzasko, John Huston, Matt A Bernstein

Abstract read
In one paragraph

Article in Physics in medicine and biology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 48% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 3 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Shengzhen TaoDepartment of Radiology, Mayo Clinic, Rochester, MN, United States of America.ORCID 0000-0003-3019-3491
Yunhong ShuMayo Clinic, 200 First Street SW, Rochester, MN 55905, United States of America.
Joshua D TrzaskoDepartment of Radiology, Mayo Clinic, Rochester, MN, United States of America.
John HustonDepartment of Radiology, Mayo Clinic, Rochester, MN, United States of America.
Matt A BernsteinDepartment of Radiology, Mayo Clinic, Rochester, MN, United States of America.
Mayo Clinic · US

Funding

High Performance, Highly Deployable Head-Only MRI ScannerR01EB010065 · NIBIB · GENERAL ELECTRIC GLOBAL RESEARCH CTR · PI BERNSTEIN, MATTHEW A., FOO, THOMAS K · 2010 to 2015
$5.5M
High-performance compact 3T MRI: Technical optimization for advanced brain imagingU01EB024450 · NIBIB · MAYO CLINIC ROCHESTER · PI BERNSTEIN, MATTHEW A., FOO, THOMAS K · 2017 to 2021
$5.3M
EXTRAMURAL RES FACIL IMPROVEMENT PROG: POLYCYSTIC KIDNEY DISEASE, RENAL STUDIES,C06RR018898 · NCRR · MAYO CLINIC · PI BURNETT, JOHN C · 2004 to 2004
$2.3M
NCRR NIH HHS C06 RR018898NIBIB NIH HHS R01 EB010065NIBIB NIH HHS U01 EB024450
6 · The paper itself

Abstract

Non-Cartesian MRI acquisition has demonstrated various advantages in many clinical applications. The shells trajectory is a 3D non-Cartesian MRI acquisition technique that samples the k-space using a series of concentric shells to achieve efficient 3D isotropic acquisition. Partial Fourier acquisition is an acceleration technique that is widely used in Cartesian MRI. It exploits the conjugate symmetry of k-space measurement to reduce the number of k-space samples compared to full-k-space acquisition, without loss of spatial resolution. For a Cartesian MRI acquisition, the direction of partial Fourier acceleration is aligned either with the phase encoded or frequency encoded direction. In those cases, the underlying image matrix can be reconstructed from the undersampled k-space data using a non-iterative, homodyne reconstruction framework. However, designing a non-Cartesian acquisition trajectory that is compatible with non-iterative homodyne reconstruction is not nearly as straightforward as in the Cartesian case. One reason is the non-iterative homodyne reconstruction requires (slightly over) half of the k-space to be fully sampled. Since the direction of partial Fourier acceleration varies throughout the acquisition in the non-Cartesian trajectory, directly applying the same partial Fourier acquisition pattern (as in Cartesian acquisitions) to a non-Cartesian trajectory does not necessarily yield a continuous, physically-achievable trajectory. In this work, we develop an asymmetric shells trajectory with fully-automated trajectory and gradient waveform design to achieve partial Fourier acquisition for the shells trajectory. We then demonstrate a non-iterative image reconstruction framework for the proposed trajectory. Phantom and in vivo brain scans based on spoiled gradient echo (SPGR) shells and magnetization-prepared shells (MP-shells) were performed to test the proposed trajectory design and reconstruction method. Our phantom and in vivo results demonstrate that the proposed partial Fourier shells trajectory maintains the desirable image contrast and high sampling efficiency from the fully sampled shells, while further reducing data acquisition time.

Indexed as

AlgorithmsPhantoms, ImagingBrainHealthy VolunteersHumansImage Processing, Computer-AssistedImaging, Three-DimensionalMagnetic Resonance Imaging

Identifiers

PMID30625455
PMCPMC6454926
OpenAlexW2910158367

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.