Observational studyJournal of radiation research2019
New real-time patient radiation dosimeter for use in radiofrequency catheter ablation.
Observational study in Journal of radiation research, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
24 citing papers in PubMed, 37 citations in OpenAlex.
- Transition from a detector-dose-based to a CNR-based cerebral angiography system: evaluation of image quality and radiation dose.Radiological physics and technology · 2026Article
- Fundamental study of digital subtraction angiography using dose characteristic analysis of different protocols in lower limb arterial disease.Fukushima journal of medical science · 2026Article
- Evaluation of radiation protection by lead glasses for interventional radiology physicians wearing prescription glasses: considering dose reduction by prescription glasses excluding lead.Journal of radiation research · 2025Article
- Assessment of lens absorbed dose by radiological technologists during mobile X-ray radiography: a comparison between computed radiography and flat panel detector systems.Radiological physics and technology · 2025Article
- Radiation dose to the eye of physicians during radio frequency catheter ablation: a small-scale study.Irish journal of medical science · 2024Review
- Real time eye dose reduction in fluoroscopy with auditory and visual feedback dosimeter through swine model experiments.Scientific reports · 2024Article
- Effect of backscatter radiation on the occupational eye-lens dose.Journal of radiation research · 2024Article
- Reduction of radiation dose using real-time visual feedback dosimetry during angiographic interventions.Journal of applied clinical medical physics · 2023Article
- Evaluation of radiation dose for inferior vena cava filter placement during pregnancy: A comparison of dosimetry and dose calculation software.Journal of applied clinical medical physics · 2023Article
- Awareness of Medical Radiologic Technologists of Ionizing Radiation and Radiation Protection.International journal of environmental research and public health · 2022Article
- Development of a New Radiation Shield for the Face and Neck of IVR Physicians.Bioengineering (Basel, Switzerland) · 2022Article
- What are useful methods to reduce occupational radiation exposure among radiological medical workers, especially for interventional radiology personnel?Radiological physics and technology · 2022Review
- Occupational eye dose correlation with neck dose and patient-related quantities in interventional cardiology procedures.Radiological physics and technology · 2022Article
- Lens dose reduction with a bismuth shield in neuro cone-beam computed tomography: an investigation on optimum shield device placement conditions.Radiological physics and technology · 2022Article
- Non-Lead Protective Aprons for the Protection of Interventional Radiology Physicians from Radiation Exposure in Clinical Settings: An Initial Study.Diagnostics (Basel, Switzerland) · 2021Article
- Patients' Radiation Shielding in Interventional Radiology Settings: A Systematic Review.Cureus · 2021Review
- Evaluation of novel X-ray protective eyewear in reducing the eye dose to interventional radiology physicians.Journal of radiation research · 2021Article
- Fetal radiation dose of four tube voltages in abdominal CT examinations during pregnancy: A phantom study.Journal of applied clinical medical physics · 2021Article
- Optimization of the Maximum Skin Dose Measurement Technique Using Digital Imaging and Communication in Medicine-Radiation Dose Structured Report Data for Patients Undergoing Cerebral Angiography.Diagnostics (Basel, Switzerland) · 2020Article
- Hybrid Operating Room System for the Treatment of Thoracic and Abdominal Aortic Aneurysms: Evaluation of the Radiation Dose Received by Patients.Diagnostics (Basel, Switzerland) · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In a previous study, we reported on a novel (prototype) real-time patient dosimeter with non-toxic phosphor sensors. In this study, we developed new types of sensors that were smaller than in the previous prototype, and clarified the clinical feasibility of our newly proposed dosimeter. Patient dose measurements obtained with the newly proposed real-time dosimeter were compared with measurements obtained using a calibrated radiophotoluminescence glass reference dosimeter (RPLD). The reference dosimeters were set at almost the same positions as the new real-time dosimeter sensors. We found excellent correlations between the reference RPLD measurements and those obtained using our new real-time dosimeter (r2 = 0.967). However, the new type of dosimeter was found to underestimate radiation skin dose measurements when compared with an RPLD. The most probable reason for this was the size reduction in the phosphor sensor of the new type of dosimeter. We believe that, as a result of reducing the phosphor sensor size, the backscattered X-ray irradiation was underestimated. However, the new dosimeter can accurately determine the absorbed dose by correcting the measured value with calibration factors. The calibration factor for the new type dosimeter was determined (by linear regression) to be ~1.15. New real-time patient dosimeter design would be an effective tool for the real-time measurement of patient skin doses during interventional radiology treatments.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.