Evidence map›Paper›PMID 30624313›Full record

ArticleClinical orthopaedics and related research2019

Differences in Femoral Torsion Among Various Measurement Methods Increase in Hips With Excessive Femoral Torsion.

Florian Schmaranzer, Till D Lerch, Klaus A Siebenrock, Moritz Tannast, Simon D Steppacher

Open access · greenAbstract readComparative Study
In one paragraph

Article in Clinical orthopaedics and related research, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 88 papers, 4 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
88citing papers in PubMed, 4 pooled it
16.8field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

88 citing papers in PubMed, 4 syntheses or guidelines pooled it, 141 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Best Practices: Hip Femoroacetabular Impingement.AJR. American journal of roentgenology · 2021
    Pooled it
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. Article
  14. Article
  15. Article
  16. Article
  17. Review
  18. Article
  19. Article
  20. Article

28 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors at 1 institution in 4 countries.

Florian SchmaranzerDepartment of Orthopaedic Surgery, Inselspital Bern, University of Bern, Bern, Switzerland.
Till D Lerch
Klaus A Siebenrock
Moritz Tannast
Simon D Steppacher
University of Bern · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCorrect quantification of femoral torsion is crucial to diagnose torsional deformities, make an indication for surgical treatment, or plan the amount of correction. However, no clear evaluation of different femoral torsion measurement methods for hips with excessive torsion has been performed to date. QUESTIONS/PURPOSES: (1) How does CT-based measurement of femoral torsion differ among five commonly used measurement methods? (2) Do differences in femoral torsion among measurement methods increase in hips with excessive femoral torsion? (3) What is the reliability and reproducibility of each of the five torsion measurement methods?

methodsBetween March and August 2016, we saw 86 new patients (95 hips) with hip pain and physical findings suggestive for femoroacetabular impingement at our outpatient tertiary clinic. Of those, 56 patients (62 hips) had a pelvic CT scan including the distal femur for measurement of femoral torsion. We excluded seven patients (seven hips) with previous hip surgery, two patients (two hips) with sequelae of Legg-Calvé-Perthes disease, and one patient (one hip) with a posttraumatic deformity. This resulted in 46 patients (52 hips) in the final study group with a mean age of 28 ± 9 years (range, 17-51 years) and 27 female patients (59%). Torsion was compared among five commonly used assessment measures, those of Lee et al., Reikerås et al., Jarrett et al., Tomczak et al., and Murphy et al. They differed regarding the level of the anatomic landmark for the proximal femoral neck axis; the method of Lee had the most proximal definition followed by the methods of Reikerås, Jarrett, and Tomczak at the base of the femoral neck and the method of Murphy with the most distal definition at the level of the lesser trochanter. The definition of the femoral head center and of the distal reference was consistent for all five measurement methods. We used the method described by Murphy et al. as our baseline measurement method for femoral torsion because it reportedly most closely reflects true anatomic femoral torsion. With this method we found a mean femoral torsion of 28 ± 13°. Mean values of femoral torsion were compared among the five methods using multivariate analysis of variance. All differences between two of the measurement methods were plotted over the entire range of femoral torsion to evaluate a possible increase in hips with excessive femoral torsion. All measurements were performed by two blinded orthopaedic residents (FS, TDL) at two different occasions to measure intraobserver reproducibility and interobserver reliability using intraclass correlation coefficients (ICCs).

resultsWe found increasing values for femoral torsion using measurement methods with a more distal definition of the proximal femoral neck axis: Lee et al. (most proximal definition: 11° ± 11°), Reikerås et al. (15° ± 11°), Jarrett et al. (19° ± 11°), Tomczak et al. (25° ± 12°), and Murphy et al. (most distal definition: 28° ± 13°). The most pronounced difference was found for the comparison between the methods of Lee et al. and Murphy et al. with a mean difference of 17° ± 5° (95% confidence interval, 16°-19°; p < 0.001). For six of 10 possible pairwise comparisons, the difference between two methods increased with increasing femoral torsion and decreased with decreasing femoral torsion. We observed a fair-to-strong linear correlation (R range, 0.306-0.622; all p values < 0.05) for any method compared with the Murphy method and for the Reikerås and Jarrett methods when compared with the Tomczak method. For example, a hip with 10° of femoral antetorsion according Murphy had a torsion of 1° according to Reikerås, which corresponds to a difference of 9°. This difference increased to 20° in hips with excessive torsion; for example, a hip with 60° of torsion according to Murphy had 40° of torsion according to Reikerås. All five methods for measuring femoral torsion showed excellent agreement for both intraobserver reproducibility (ICC, 0.905-0.973) and interobserver reliability (ICC, 0.938-0.969).

conclusionsBecause the quantification of femoral torsion in hips with excessive femoral torsion differs considerably among measurement methods, it is crucial to state the applied methods when reporting femoral torsion and to be consistent regarding the used measurement method. These differences have to be considered for surgical decision-making and planning the degree of correction. Neglecting the differences among measurement methods to quantify femoral torsion can potentially lead to misdiagnosis and surgical planning errors. LEVEL OF EVIDENCE: Level IV, diagnostic study.

Indexed as

Tomography, X-Ray ComputedAdolescentAdultAnatomic LandmarksBiomechanical PhenomenaFemaleFemoracetabular ImpingementFemurHip JointHumansMaleMiddle AgedPredictive Value of TestsReproducibility of ResultsRetrospective StudiesTorsion Abnormality

Identifiers

PMID30624313
PMCPMC6494336
OpenAlexW2914786393

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.