Evidence map›Paper›PMID 30623618›Full record

ArticleAnnals of laboratory medicine2019

Dried Blood Spot Multiplexed Steroid Profiling Using Liquid Chromatography Tandem Mass Spectrometry in Korean Neonates.

Rihwa Choi, Hyung Doo Park, Hyeon Ju Oh, Kyounghoon Lee, Junghan Song, Soo Youn Lee

Open access · diamondAbstract read
In one paragraph

Article in Annals of laboratory medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
2.4field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 27 citations in OpenAlex.

  1. Trial
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. Article
  14. Review
  15. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Rihwa ChoiDepartment of Laboratory Medicine, Green Cross Laboratories, Yongin, Korea.
Hyung Doo ParkDepartment of Laboratory Medicine and Genetics, Samsung Medical Center, Seoul, Korea.ORCID 0000-0003-1798-773X
Hyeon Ju OhDepartment of Laboratory Medicine and Genetics, Samsung Medical Center, Seoul, Korea.
Kyounghoon LeeDepartment of Laboratory Medicine and Genetics, Samsung Medical Center, Seoul, Korea.
Junghan SongDepartment of Laboratory Medicine, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam, Korea.
Soo Youn LeeDepartment of Laboratory Medicine and Genetics, Samsung Medical Center, Seoul, Korea.ORCID 0000-0001-7595-4042
Samsung Medical Center · KRGreen Cross (South Korea) · KRSeoul National University Bundang Hospital · KR

Funding

Ministry of Health and Welfare A120030
6 · The paper itself

Abstract

backgroundScreening for congenital adrenal hyperplasia (CAH) using immunoassays for 17α-hydroxyprogesterone generates many false-positive results. We developed and validated a liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for simultaneous quantification of nine steroid hormones in dried blood spot (DBS) samples, and established reference intervals for these hormones.

methodsWe examined our method for linearity, precision, accuracy, extraction recovery, and matrix effects and determined the reference intervals of cortisol, 17α-hydroxyproges-terone, 11-deoxycortisol, 21-deoxycortisol, androstenedione, corticosterone, 11-deoxycorticosterone, testosterone, and progesterone in 1,146 DBS samples (from 272 preterm and 874 full-term neonates). Immunoassay and LC-MS/MS methods were compared for 17α-hydroxyprogesterone. Fourteen additional samples were tested to validate the clinical applicability of the LC-MS/MS method.

resultsThe linearity range was 2.8-828.0 nmol/L for cortisol and 0.9-40.0 nmol/L for the other steroids (R²>0.99). Intra-day and inter-day precision CVs were 2.52-12.26% and 3.53-17.12%, respectively. Accuracy was 80.81-99.94%, and extraction recovery and matrix effects were 88.0-125.4% and 61.7-74.2%, respectively. There was a negative bias, with higher values measured by immunoassay compared with LC-MS/MS (

conclusionsOur method enables highly sensitive and specific assessment of nine steroids from DBS and is a promising tool for clinical analysis of CAH.

Indexed as

Tandem Mass Spectrometry17-alpha-HydroxyprogesteroneAdrenal Hyperplasia, CongenitalChromatography, High Pressure LiquidDried Blood Spot TestingHumansInfant, NewbornLimit of DetectionReference ValuesReproducibility of ResultsRepublic of KoreaSteroids17-alpha-HydroxyprogesteroneSteroids17α-hydroxyprogesteroneCongenital adrenal hyperplasiaDried blood spotLC-MS/MSreference intervalsSteroid hormones

Identifiers

PMID30623618
PMCPMC6340850
OpenAlexW2909058683

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.