Evidence map›Paper›PMID 30620742›Full record

ArticlePloS one2019

Monte-Carlo simulation of the Siemens Artiste linear accelerator flat 6 MV and flattening-filter-free 7 MV beam line.

Alemeh Sadrollahi, Frank Nuesken, Norbert Licht, Christian Rübe, Yvonne Dzierma

Abstract read
In one paragraph

Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Effect of plan complexity on the dosimetry, delivery accuracy, and interplay effect in lung VMAT SBRT with 6 MV FFF beam.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2022
    Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Alemeh SadrollahiDepartment of Radiotherapy and Radiation Oncology, Saarland University Medical Center, Homburg, Saarland, Germany.ORCID 0000-0002-1314-1182
Frank NueskenDepartment of Radiotherapy and Radiation Oncology, Saarland University Medical Center, Homburg, Saarland, Germany.
Norbert LichtDepartment of Radiotherapy and Radiation Oncology, Saarland University Medical Center, Homburg, Saarland, Germany.
Christian RübeDepartment of Radiotherapy and Radiation Oncology, Saarland University Medical Center, Homburg, Saarland, Germany.
Yvonne DziermaDepartment of Radiotherapy and Radiation Oncology, Saarland University Medical Center, Homburg, Saarland, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The aim of our work is to provide the up-to-now missing information on the Siemens Artiste FFF 7 MV beam line using a Monte-Carlo model fit to the realistic dosimetric measurements at the linear accelerator in clinical use at our department. The main Siemens Artiste 6MV and FFF 7MV beams were simulated using the Geant4 toolkit. The simulations were compared with the measurements with an ionization chamber in a water phantom to verify the validation of simulation and tuning the primary electron parameters. Hereafter, other parameters such as surface dose, spectrum, electron contamination, symmetry, flatness/unflatness, slope, and characteristic off-axis changes were discussed for both Flat and FFF mode. The mean electron energy for the FFF beam was 8.8 MeV and 7.5 MeV for Flat 6 MV, the spread energy and spot size of the selected Gaussian distribution source were 0.4 MeV and 1mm, respectively. The dose rate of the FFF beam was 2.8 (2.96) times higher than for the flattened beam for a field size of 10×10 (20×20) cm2. The electron contamination has significant contribution to the surface dose especially for the flattened beam. The penumbra, surface dose and the mean energy of photons decrease by removing the flattening filter. Finally, the results show that off-axis changes have no strong effect on the mean energy of FFF beams, while this effect was more considerable for the flattened beam.

Indexed as

ElectronsMonte Carlo MethodParticle AcceleratorsPhotonsPhysical PhenomenaRadiometryRadiotherapy DosageRadiotherapy Planning, Computer-AssistedReproducibility of Results

Identifiers

PMID30620742
PMCPMC6324801

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.