Evidence map›Paper›PMID 30619648›Full record

ArticleTranslational vision science & technology2018

Unintentional Movements During the Use of Vitreoretinal Forceps.

Mahmut Dogramaci, David H Steel

Open access · goldAbstract read
In one paragraph

Article in Translational vision science & technology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.5field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 2 institutions in 1 country.

Mahmut DogramaciPrincess Alexandra Hospital NHS Trust, Hamstel Road, Harlow, Essex, UK.
David H SteelSunderland Eye Infirmary, Queen Alexandra Rd, Sunderland SR2 9HP, Institute of Genetic Medicine, Newcastle University, Newcastle Upon Tyne, UK.
Princess Alexandra Hospital NHS Trust · GBSunderland Eye Infirmary · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeIntraocular forceps used in vitreoretinal surgery are actuated by squeezing their handles. We studied the relationship between actuation and any accompanying unintentional movements of the instrument tip, and compared different handle designs and gauges.

methodsOptical sensors were used to measure involuntary movements of forceps tips while monitoring the extent of actuation. Mean root mean square (RMS) and ranges of signals obtained from sensors were computed before and after applying high (7-13 Hz) and low (<5 Hz) frequency filters. Four handle designs, two gauge sizes, and two users were compared to each other.

resultsIn the absence of human contact, mean RMS of noise was 6.47 μ and mean range was 21.67 μ. When the forceps were held by the surgeon but kept motionless (no actuation), mean RMS was 58.01 μ and mean range was 156.66 μ. When the forceps were actuated, mean RMS was 214.71 μ and mean range was 566.11 μ. The differences were statistically significant (

conclusionsActuating forceps was associated directly with increased unintentional low frequency movements at the tip of the forceps when held by hand. TRANSLATIONAL RELEVANCE: A novel system of measuring unintentional forceps tip movement during actuation is described which could be used to guide improved design.

Indexed as

epiretinal membrane peelinternal limiting membrane peelintraocular forcepsmicrosurgerypneumatic forcepssurgical skillstremorvitrectomyvitreoretinal surgery

Identifiers

PMID30619648
PMCPMC6314061
OpenAlexW2905693575

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.