Evidence map›Paper›PMID 30618277›Full record

SynthesisEuropean heart journal. Acute cardiovascular care2020

Serial high-sensitivity cardiac troponin T measurements to rule out acute myocardial infarction and a single high baseline measurement for swift rule-in: A systematic review and meta-analysis.

M Arslan, A Dedic, E Boersma, E A Dubois

Open access · hybridAbstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in European heart journal. Acute cardiovascular care, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
3.2field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 32 citations in OpenAlex.

  1. Observational
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Review
  8. How Close Are We to Patient-Side Troponin Testing?Journal of clinical medicine · 2024
    Review
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Review
  16. Article
  17. Article
  18. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

M ArslanDepartment of Cardiology, Erasmus Medical Centre, The Netherlands.
A DedicDepartment of Cardiology, Erasmus Medical Centre, The Netherlands.
E BoersmaDepartment of Cardiology, Erasmus Medical Centre, The Netherlands.
E A DuboisDepartment of Cardiology, Erasmus Medical Centre, The Netherlands.
Erasmus University Rotterdam · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimsThe purpose of this study was to determine (a) the ability of serial high-sensitivity cardiac troponin T measurements to rule out acute myocardial infarction and (b) the ability of a single high baseline high-sensitivity cardiac troponin T measurement to rule in acute myocardial infarction in patients presenting to the emergency department with acute chest pain. METHODS AND

resultsEmbase, Medline, Cochrane, Web of Science and Google scholar were searched for prospective cohort studies that evaluated parameters of diagnostic accuracy of serial high-sensitivity cardiac troponin T to rule out acute myocardial infarction and a single baseline high-sensitivity cardiac troponin T value>50 ng/l to rule in acute myocardial infarction. The search yielded 21 studies for the systematic review, of which 14 were included in the meta-analysis, with a total of 11,929 patients and an overall prevalence of acute myocardial infarction of 13.0%. For rule-out, six studies presented the sensitivity of serial measurements <14 ng/l. This cut-off classified 60.1% of patients as rule-out and the summary sensitivity was 96.7% (95% confidence interval: 92.3-99.3). Three studies presented the sensitivity of a one-hour algorithm with a baseline high-sensitivity cardiac troponin T value<12 ng/l and delta 1 hour <3 ng/l. This algorithm classified 60.2% of patients as rule-out and the summary sensitivity was 98.9% (96.4-100). For rule-in, six studies reported the specificity of baseline high-sensitivity cardiac troponin T value>50 ng/l. The summary specificity was 94.6% (91.5-97.1).

conclusionSerial high-sensitivity cardiac troponin T measurement strategies to rule out acute myocardial infarction perform well, and a single baseline high-sensitivity cardiac troponin T value>50 ng/l to rule in acute myocardial infarction has a high specificity.

Indexed as

Acute DiseaseAdultAgedAged, 80 and overAlgorithmsChest PainEmergency Service, HospitalFemaleHumansMaleMiddle AgedMyocardial InfarctionPrevalenceProspective StudiesSensitivity and SpecificityTroponin TTroponin TAcute myocardial infarctionhigh-sensitivity cardiac troponin Trule-inrule-out

Identifiers

PMID30618277
PMCPMC7008551
OpenAlexW2908751387

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked