Evaluation of pressure-controlled mammography compression paddles with respect to force-controlled compression paddles in clinical practice.

C R L P N Jeukens, T van Dijk, C Berben, J E Wildberger, M B I Lobbes

Abstract read
In one paragraph

Article in European radiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

C R L P N JeukensDepartment of Radiology and Nuclear Medicine, Maastricht University Medical Center, P. Debyelaan 25, PO Box 5800, 6202AZ, Maastricht, The Netherlands. Cecile.Jeukens@mumc.nl.ORCID http://orcid.org/0000-0003-1403-8301
T van DijkDepartment of Radiology and Nuclear Medicine, Maastricht University Medical Center, P. Debyelaan 25, PO Box 5800, 6202AZ, Maastricht, The Netherlands.
C BerbenDepartment of Radiology and Nuclear Medicine, Maastricht University Medical Center, P. Debyelaan 25, PO Box 5800, 6202AZ, Maastricht, The Netherlands.
J E WildbergerDepartment of Radiology and Nuclear Medicine, Maastricht University Medical Center, P. Debyelaan 25, PO Box 5800, 6202AZ, Maastricht, The Netherlands.
M B I LobbesDepartment of Radiology and Nuclear Medicine, Maastricht University Medical Center, P. Debyelaan 25, PO Box 5800, 6202AZ, Maastricht, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo reduce pain and discomfort associated with breast compression in mammography, a pressure-controlled compression paddle was recently introduced. The objective was to evaluate the pressure-controlled paddle by comparing it to the standard force-controlled paddle.

methodsDifferences of compressed breast thickness (CBT), compression force, compression pressure, and average glandular dose (AGD) between annual follow-up full-field digital mammography exams of 3188 patients were retrospectively examined. Two groups were compared: (1) force-force group (FF-group), both examinations were performed with the force-controlled paddle, and (2) force-pressure group (FP-group), only the follow-up examination was performed with the pressure-controlled paddle. In an additional group of patients, pain scores on a scale of 0 (no pain at all) to 10 (worst pain imaginable) were evaluated prospectively (n = 343) who were randomly assigned to either paddle.

resultsMedian differences between follow-up exams in CBT, compression force, compression pressure, and AGD were for the FF- and FP-group respectively - 1.0 vs 0.0 mm (p < 0.001); 0.0 vs - 1.0 daN (p = 0.002); - 1.0 vs - 0.5 kPa (p = 0.005); and 0.05 vs - 0.02 mGy (p < 0.001). These differences were, although statistically significant, clinically non-relevant (defined as ΔCBT > ± 2 mm; Δforce > ± 2 daN; Δpressure > ± 1 kPa and ΔAGD > ± 0.1 mGy). The subanalysis dividing CBT into five categories revealed similar results. The median [interquartile range] pain scores were 6 [3, 7] and 5 [3, 7] for the force-controlled and pressure-controlled paddle, respectively, which was not significantly different (p = 0.113).

conclusionsWe observed no clinically relevant differences in CBT, compression force, compression pressure, AGD, or pain score between the force- and pressure-controlled paddle. As such, we found no basis for preferring one paddle over the other. KEY POINTS: • The pressure-controlled paddle did not show any clinically relevant changes in breast compression parameters compared to the force-controlled paddle. • The pressure-controlled paddle did not lead to significant reduction in pain scores indicated by the patients compared to the force-controlled paddle. • A large variation in compression force and compression pressure was observed in mammography exams for the both the force- and pressure-controlled compression paddle.

Indexed as

AgedBreastBreast NeoplasmsFemaleHumansMammographyMiddle AgedPainPain MeasurementPressureRetrospective StudiesYoung AdultMammographyPainRadiation dosage

Identifiers

PMID30617472
PMCPMC6443616

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.