Evidence map›Paper›PMID 30616683›Full record

ArticleJournal of neuroengineering and rehabilitation2019

Stimulation of paralysed quadriceps muscles with sequentially and spatially distributed electrodes during dynamic knee extension.

Marco Laubacher, Efe A Aksoez, Anne K Brust, Michael Baumberger, Robert Riener, Stuart Binder-Macleod, Kenneth J Hunt

Open access · goldAbstract read
In one paragraph

Article in Journal of neuroengineering and rehabilitation, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
1.8field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 30 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Multi-Channel Functional Electrical Stimulation to Improve Specificity of Hand Extension.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2025
    Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Marco LaubacherDepartment of Physical Therapy, University of Delaware, Newark, United States of America. marco.laubacher@bfh.ch.ORCID 0000-0002-7267-2231
Efe A AksoezDepartment of Physical Therapy, University of Delaware, Newark, United States of America.
Anne K BrustDepartment of Physical Therapy, University of Delaware, Newark, United States of America.
Michael BaumbergerInstitute for Rehabilitation and Performance Technology, Division of Mechanical Engineering, Department of Engineering and Information Technology, Bern University of Applied Sciences, Pestalozzistrasse 20, Burgdorf, 3400, Switzerland.
Robert RienerInstitute for Rehabilitation and Performance Technology, Division of Mechanical Engineering, Department of Engineering and Information Technology, Bern University of Applied Sciences, Pestalozzistrasse 20, Burgdorf, 3400, Switzerland.
Stuart Binder-MacleodSwiss Paraplegic Centre, Nottwil, 6207, Switzerland.
Kenneth J HuntSwiss Paraplegic Centre, Nottwil, 6207, Switzerland.
University of Delaware · USBern University of Applied Sciences · CHSwiss Paraplegic Research · CH

Funding

Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung 15128/1
6 · The paper itself

Abstract

backgroundDuring functional electrical stimulation (FES) tasks with able-bodied (AB) participants, spatially distributed sequential stimulation (SDSS) has demonstrated substantial improvements in power output and fatigue properties compared to conventional single electrode stimulation (SES). The aim of this study was to compare the properties of SDSS and SES in participants with spinal cord injury (SCI) in a dynamic isokinetic knee extension task simulating knee movement during recumbent cycling.

methodUsing a case-series design, m. vastus lateralis and medialis of four participants with motor and sensory complete SCI (AIS A) were stimulated for 6 min on both legs with both electrode setups. With SES, target muscles were stimulated by a pair of electrodes. In SDSS, the distal electrodes were replaced by four small electrodes giving the same overall stimulation frequency and having the same total surface area. Torque was measured during knee extension by a dynamometer at an angular velocity of 110 deg/s. Mean power of the left and right sides (P

resultsSDSS showed higher P

conclusionConsistently higher P

Indexed as

AdultElectric Stimulation TherapyElectrodesFemaleHumansKnee JointMaleMuscle FatigueParalysisQuadriceps MuscleSpinal Cord InjuriesYoung AdultFatigueFunctional electrical stimulationKnee dynamometerPower outputRehabilitationSpatially distributed sequential stimulationSpinal cord injury

Identifiers

PMID30616683
PMCPMC6322281
OpenAlexW2947323249

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.