Evidence map›Paper›PMID 30615721›Full record

ArticleBiomedical optics express2018

Multi-beam scan analysis with a clinical LINAC for high resolution Cherenkov-excited molecular luminescence imaging in tissue.

Mengyu Jeremy Jia, Petr Bruza, Lesley A Jarvis, David J Gladstone, Brian W Pogue

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.4field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Mengyu Jeremy JiaThayer School of Engineering, Dartmouth College, Hanover, NH 03755, USA.
Petr BruzaThayer School of Engineering, Dartmouth College, Hanover, NH 03755, USA.
Lesley A JarvisDepartment of Medicine, Geisel School of Medicine, Dartmouth College, Hanover, NH 03755, USA.
David J GladstoneThayer School of Engineering, Dartmouth College, Hanover, NH 03755, USA.
Brian W PogueThayer School of Engineering, Dartmouth College, Hanover, NH 03755, USA.
Dartmouth College · US

Funding

Cerenkov excited luminescence sheet imaging (CELSI)R01EB024498 · NIBIB · DARTMOUTH COLLEGE · PI POGUE, BRIAN WILLIAM · 2017 to 2020
$2.2M
NIBIB NIH HHS R01 EB024498
6 · The paper itself

Abstract

Cherenkov-excited luminescence scanned imaging (CELSI) is achieved with external beam radiotherapy to map out molecular luminescence intensity or lifetime in tissue. Just as in fluorescence microscopy, the choice of excitation geometry can affect the imaging time, spatial resolution and contrast recovered. In this study, the use of spatially patterned illumination was systematically studied comparing scan shapes, starting with line scan and block patterns and increasing from single beams to multiple parallel beams and then to clinically used treatment plans for radiation therapy. The image recovery was improved by a spatial-temporal modulation-demodulation method, which used the ability to capture simultaneous images of the excitation Cherenkov beam shape to deconvolve the CELSI images. Experimental studies used the multi-leaf collimator on a clinical linear accelerator (LINAC) to create the scanning patterns, and image resolution and contrast recovery were tested at different depths of tissue phantom material. As hypothesized, the smallest illumination squares achieved optimal resolution, but at the cost of lower signal and slower imaging time. Having larger excitation blocks provided superior signal but at the cost of increased radiation dose and lower resolution. Increasing the scan beams to multiple block patterns improved the performance in terms of image fidelity, lower radiation dose and faster acquisition. The spatial resolution was mostly dependent upon pixel area with an optimized side length near 38mm and a beam scan pitch of

Indexed as

(170.3010) Image reconstruction techniques(170.3880) Medical and biological imaging(170.6920) Time-resolved imaging(170.7440) X-ray imaging(260.3800) Luminescence

Identifiers

PMID30615721
PMCPMC6157777
OpenAlexW2886720126

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.