Evidence map›Paper›PMID 30612574›Full record

ArticleJournal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance2019

Machine learning derived segmentation of phase velocity encoded cardiovascular magnetic resonance for fully automated aortic flow quantification.

Alex Bratt, Jiwon Kim, Meridith Pollie, Ashley N Beecy, Nathan H Tehrani, Noel Codella, Rocio Perez-Johnston, Maria Chiara Palumbo, Javid Alakbarli, Wayne Colizza and 5 more

Open access · goldAbstract readMulticenter StudyValidation Study
In one paragraph

Article in Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 37 papers.

0numbers the graph read from it
0cells of the map it votes in
37citing papers in PubMed
9.6field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

37 citing papers in PubMed, 87 citations in OpenAlex.

  1. Review
  2. Article
  3. Observational
  4. Article
  5. Article
  6. Article
  7. Review
  8. Review
  9. Review
  10. Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Review
  16. Review
  17. Article
  18. Review
  19. The Role of Cardiac Magnetic Resonance in Aortic Stenosis and Regurgitation.Journal of cardiovascular development and disease · 2022
    Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

15 authors at 4 institutions in 1 country.

Alex BrattDepartment of Radiology, Weill Cornell Medicine, 525 E 68th St, New York, NY, 10065, USA.
Jiwon KimDepartment of Radiology, Weill Cornell Medicine, 525 E 68th St, New York, NY, 10065, USA.
Meridith PollieGreenberg Division of Cardiology, Department of Medicine, Weill Cornell Medicine, 525 E 68th St, New York, NY, 10065, USA.
Ashley N BeecyGreenberg Division of Cardiology, Department of Medicine, Weill Cornell Medicine, 525 E 68th St, New York, NY, 10065, USA.
Nathan H TehraniGreenberg Division of Cardiology, Department of Medicine, Weill Cornell Medicine, 525 E 68th St, New York, NY, 10065, USA.
Noel CodellaIBM TJ Watson Research Center, 1101 Kitchawan Rd, Yorktown Heights, NY, 10598, USA.
Rocio Perez-JohnstonMemorial Sloan Kettering Cancer Center, 1275 York Ave, New York, NY, 10065, USA.
Maria Chiara PalumboGreenberg Division of Cardiology, Department of Medicine, Weill Cornell Medicine, 525 E 68th St, New York, NY, 10065, USA.
Javid AlakbarliGreenberg Division of Cardiology, Department of Medicine, Weill Cornell Medicine, 525 E 68th St, New York, NY, 10065, USA.
Wayne ColizzaDepartment of Radiology, Weill Cornell Medicine, 525 E 68th St, New York, NY, 10065, USA.
Ian R DrexlerDepartment of Radiology, Weill Cornell Medicine, 525 E 68th St, New York, NY, 10065, USA.
Clerio F AzevedoDuke Cardiovascular Magnetic Resonance Center, 10 Duke Medicine Circle, Durham, NC, 27710, USA.
Raymond J KimDuke Cardiovascular Magnetic Resonance Center, 10 Duke Medicine Circle, Durham, NC, 27710, USA.
Richard B DevereuxGreenberg Division of Cardiology, Department of Medicine, Weill Cornell Medicine, 525 E 68th St, New York, NY, 10065, USA.
Jonathan W WeinsaftDepartment of Radiology, Weill Cornell Medicine, 525 E 68th St, New York, NY, 10065, USA. jww2001@med.cornell.edu.ORCID 0000-0002-8386-0297
Cornell University · USDuke Medical Center · USMemorial Sloan Kettering Cancer Center · USIBM (United States) · US

Funding

X-RAY CRYSTALLOGRAPHYP30CA008748 · NCI · SLOAN-KETTERING INSTITUTE FOR CANCER RES · PI Nicholas D Socci · 1985 to 2026
$347.4M
CMR Myocardial Tissue Based Prediction of Ischemic MR Revascularization ResponseR01HL128278 · NHLBI · WEILL MEDICAL COLL OF CORNELL UNIV · PI WEINSAFT, JONATHAN W. · 2015 to 2019
$3.8M
Advanced CMR Tissue-Based Prediction of Right Ventricular Dysfunction and Revascularization ResponseK23HL140092 · NHLBI · WEILL MEDICAL COLL OF CORNELL UNIV · PI KIM, JIWON · 2018 to 2022
$847k
Delayed Enhancement MRI for Detection of Sub-Clinical Papillary Muscle InfarctionK23HL102249 · NHLBI · WEILL MEDICAL COLL OF CORNELL UNIV · PI WEINSAFT, JONATHAN W. · 2010 to 2014
$680k
NCI NIH HHS P30 CA008748NHLBI NIH HHS K23 HL102249NHLBI NIH HHS K23 HL140092NHLBI NIH HHS R01 HL128278
6 · The paper itself

Abstract

backgroundPhase contrast (PC) cardiovascular magnetic resonance (CMR) is widely employed for flow quantification, but analysis typically requires time consuming manual segmentation which can require human correction. Advances in machine learning have markedly improved automated processing, but have yet to be applied to PC-CMR. This study tested a novel machine learning model for fully automated analysis of PC-CMR aortic flow.

methodsA machine learning model was designed to track aortic valve borders based on neural network approaches. The model was trained in a derivation cohort encompassing 150 patients who underwent clinical PC-CMR then compared to manual and commercially-available automated segmentation in a prospective validation cohort. Further validation testing was performed in an external cohort acquired from a different site/CMR vendor.

resultsAmong 190 coronary artery disease patients prospectively undergoing CMR on commercial scanners (84% 1.5T, 16% 3T), machine learning segmentation was uniformly successful, requiring no human intervention: Segmentation time was < 0.01 min/case (1.2 min for entire dataset); manual segmentation required 3.96 ± 0.36 min/case (12.5 h for entire dataset). Correlations between machine learning and manual segmentation-derived flow approached unity (r = 0.99, p < 0.001). Machine learning yielded smaller absolute differences with manual segmentation than did commercial automation (1.85 ± 1.80 vs. 3.33 ± 3.18 mL, p < 0.01): Nearly all (98%) of cases differed by ≤5 mL between machine learning and manual methods. Among patients without advanced mitral regurgitation, machine learning correlated well (r = 0.63, p < 0.001) and yielded small differences with cine-CMR stroke volume (∆ 1.3 ± 17.7 mL, p = 0.36). Among advanced mitral regurgitation patients, machine learning yielded lower stroke volume than did volumetric cine-CMR (∆ 12.6 ± 20.9 mL, p = 0.005), further supporting validity of this method. Among the external validation cohort (n = 80) acquired using a different CMR vendor, the algorithm yielded equivalently small differences (∆ 1.39 ± 1.77 mL, p = 0.4) and high correlations (r = 0.99, p < 0.001) with manual segmentation, including similar results in 20 patients with bicuspid or stenotic aortic valve pathology (∆ 1.71 ± 2.25 mL, p = 0.25).

conclusionFully automated machine learning PC-CMR segmentation performs robustly for aortic flow quantification - yielding rapid segmentation, small differences with manual segmentation, and identification of differential forward/left ventricular volumetric stroke volume in context of concomitant mitral regurgitation. Findings support use of machine learning for analysis of large scale CMR datasets.

Indexed as

HemodynamicsMachine LearningMagnetic Resonance Imaging, CineAgedAortaAortic ValveAutomationBlood Flow VelocityFemaleHeart DiseasesHumansImage Interpretation, Computer-AssistedMaleMiddle AgedMyocardial Perfusion ImagingPredictive Value of TestsAortaCardiovascular magnetic resonanceDeep learningMachine learningPhase contrast

Identifiers

PMID30612574
PMCPMC6322266
OpenAlexW2906879808

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.