ArticleIEEE transactions on medical imaging2019
A Feasibility Study of Extracting Tissue Textures From a Previous Full-Dose CT Database as Prior Knowledge for Bayesian Reconstruction of Current Low-Dose CT Images.
Article in IEEE transactions on medical imaging, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed.
- ADMM-TransNet: ADMM-Based Sparse-View CT Reconstruction Method Combining Convolution and Transformer Network.Tomography (Ann Arbor, Mich.) · 2025Article
- Learned Tensor Neural Network Texture Prior for Photon-Counting CT Reconstruction.IEEE transactions on medical imaging · 2024Article
- Machine Learned Texture Prior From Full-Dose CT Database via Multi-Modality Feature Selection for Bayesian Reconstruction of Low-Dose CT.IEEE transactions on medical imaging · 2023Article
- A Joint-Parameter Estimation and Bayesian Reconstruction Approach to Low-Dose CT.Sensors (Basel, Switzerland) · 2023Article
- Deep learning tomographic reconstruction through hierarchical decomposition of domain transforms.Visual computing for industry, biomedicine, and art · 2022Article
- Prior-image-based CT reconstruction using attenuation-mismatched priors.Physics in medicine and biology · 2021Article
- Characterization of tissue-specific pre-log Bayesian CT reconstruction by texture-dose relationship.Medical physics · 2020Article
- Spectral CT Reconstruction via Low-Rank Representation and Region-Specific Texture Preserving Markov Random Field Regularization.IEEE transactions on medical imaging · 2020Article
- A Task-dependent Investigation on Dose and Texture in CT Image Reconstruction.IEEE transactions on radiation and plasma medical sciences · 2020Article
- Constructing a tissue-specific texture prior by machine learning from previous full-dose scan for Bayesian reconstruction of current ultralow-dose CT images.Journal of medical imaging (Bellingham, Wash.) · 2020Article
- Energy enhanced tissue texture in spectral computed tomography for lesion classification.Visual computing for industry, biomedicine, and art · 2019Article
- A Feasibility Study of Extracting Tissue Textures From a Previous Full-Dose CT Database as Prior Knowledge for Bayesian Reconstruction of Current Low-Dose CT Images.IEEE transactions on medical imaging · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
Abstract
Markov random field (MRF) has been widely used to incorporate a priori knowledge as penalty or regularizer to preserve edge sharpness while smoothing the region enclosed by the edge for pieces-wise smooth image reconstruction. In our earlier study, we proposed a type of MRF reconstruction method for low-dose CT (LdCT) scans using tissue-specific textures extracted from the same patient's previous full-dose CT (FdCT) scans as prior knowledge. It showed advantages in clinical applications. This paper aims to remove the constraint of using previous data of the same patient. We investigated the feasibility of extracting the tissue-specific MRF textures from an FdCT database to reconstruct a LdCT image of another patient. This feasibility study was carried out by experiments designed as follows. We constructed a tissue-specific MRF-texture database from 3990 FdCT scan slices of 133 patients who were scheduled for lung nodule biopsy. Each patient had one FdCT scan (120 kVp/100 mAs) and one LdCT scan (120 kVp/20 mAs) prior to biopsy procedure. When reconstructing the LdCT image of one patient among the 133 patients, we ranked the closeness of the MRF-textures from the other 132 patients saved in the database and used them as the a prior knowledge. Then, we evaluated the reconstructed image quality using Haralick texture measures. For any patient within our database, we found more than eighteen patients' FdCT MRF texures can be used without noticeably changing the Haralick texture measures on the lung nodules (to be biopsied). These experimental outcomes indicate it is promising that a sizable FdCT texture database could be used to enhance Bayesian reconstructions of any incoming LdCT scans.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.