Evidence map›Paper›PMID 30605087›Full record

ArticleIEEE transactions on bio-medical engineering2019

Computer-Aided Diagnosis of Label-Free 3-D Optical Coherence Microscopy Images of Human Cervical Tissue.

Yutao Ma, Tao Xu, Xiaolei Huang, Xiaofang Wang, Canyu Li, Jason Jerwick, Yuan Ning, Xianxu Zeng, Baojin Wang, Yihong Wang and 3 more

Open access · hybridAbstract read
In one paragraph

Article in IEEE transactions on bio-medical engineering, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
3.0field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 46 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Review
  10. Article
  11. Article
  12. Review
  13. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors at 5 institutions in 2 countries.

Yutao Ma
Tao Xu
Xiaolei Huang
Xiaofang Wang
Canyu Li
Jason Jerwick
Yuan Ning
Xianxu Zeng
Baojin Wang
Yihong Wang
Zhan Zhang
Xiaoan Zhang
Chao Zhou
Lehigh University · USThird Affiliated Hospital of Zhengzhou University · CNBrown University · USPennsylvania State University · USWuhan University · CN

Funding

High throughput optical coherence tomography (OCT)-based imaging platform for label-free, non-invasive characterization of 3D tumor spheroids.R01EB025209 · NIBIB · WASHINGTON UNIVERSITY · PI ZHOU, CHAO · 2017 to 2021
$1.4M
Integrated Optical Coherence Tomography and Microscopy for Molecular-Targeted ImaR00EB010071 · NIBIB · LEHIGH UNIVERSITY · PI ZHOU, CHAO · 2012 to 2013
$479k
Integrated Optical Coherence Tomography and Microscopy for Molecular-Targeted ImaK99EB010071 · NIBIB · MASSACHUSETTS INSTITUTE OF TECHNOLOGY · PI ZHOU, CHAO · 2011 to 2011
$90k
NIBIB NIH HHS K99 EB010071NIBIB NIH HHS R00 EB010071NIBIB NIH HHS R01 EB025209
6 · The paper itself

Abstract

objectiveUltrahigh-resolution optical coherence microscopy (OCM) has recently demonstrated its potential for accurate diagnosis of human cervical diseases. One major challenge for clinical adoption, however, is the steep learning curve clinicians need to overcome to interpret OCM images. Developing an intelligent technique for computer-aided diagnosis (CADx) to accurately interpret OCM images will facilitate clinical adoption of the technology and improve patient care.

methods497 high-resolution three-dimensional (3-D) OCM volumes (600 cross-sectional images each) were collected from 159 ex vivo specimens of 92 female patients. OCM image features were extracted using a convolutional neural network (CNN) model, concatenated with patient information [e.g., age and human papillomavirus (HPV) results], and classified using a support vector machine classifier. Ten-fold cross-validations were utilized to test the performance of the CADx method in a five-class classification task and a binary classification task.

resultsAn 88.3 ± 4.9% classification accuracy was achieved for five fine-grained classes of cervical tissue, namely normal, ectropion, low-grade and high-grade squamous intraepithelial lesions (LSIL and HSIL), and cancer. In the binary classification task [low-risk (normal, ectropion, and LSIL) versus high-risk (HSIL and cancer)], the CADx method achieved an area-under-the-curve value of 0.959 with an 86.7 ± 11.4% sensitivity and 93.5 ± 3.8% specificity.

conclusionThe proposed deep-learning-based CADx method outperformed four human experts. It was also able to identify morphological characteristics in OCM images that were consistent with histopathological interpretations. SIGNIFICANCE: Label-free OCM imaging, combined with deep-learning-based CADx methods, holds a great promise to be used in clinical settings for the effective screening and diagnosis of cervical diseases.

Indexed as

AlgorithmsCervix UteriDeep LearningFemaleHumansImage Interpretation, Computer-AssistedImaging, Three-DimensionalMicroscopyTomography, Optical CoherenceUterine Cervical Diseases

Identifiers

PMID30605087
PMCPMC6724217
OpenAlexW2893683567

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.