Evidence map›Paper›PMID 30604310›Full record

ArticleJournal of cardiovascular translational research2019

A Novel Wireless Left Atrial Pressure Monitoring System for Patients with Heart Failure, First Ex-Vivo and Animal Experience.

Leor Perl, Elina Soifer, Jozef Bartunek, Dedi Erdheim, Friedrich Köhler, William T Abraham, David Meerkin

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Journal of cardiovascular translational research, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
22citing papers in PubMed, 1 pooled it
4.3field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

22 citing papers in PubMed, 1 synthesis or guideline pooled it, 42 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Review
  4. Review
  5. Review
  6. Review
  7. Article
  8. Review
  9. Review
  10. Review
  11. Article
  12. Review
  13. Article
  14. Review
  15. Article
  16. Review
  17. Telemonitoring in Heart Failure Management.Cardiac failure review · 2020
    Review
  18. Review
  19. Review
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 5 institutions in 4 countries.

Leor PerlThe Division of Cardiology, Rabin Medical Center, 39 Jabotinsky Street, Petach-Tikva, Israel. leorperl@gmail.com.ORCID 0000-0002-0625-7937
Elina SoiferVectorious Medical Technologies, 24 Raul Wallenberg St., Tel-Aviv, Israel.
Jozef BartunekCardiovascular Center, Onze-Lieve-Vrouwziekenhuis OLV Hospital, Moorselbaan 164, Aalst, B-9300, Aalst, Belgium.
Dedi ErdheimVectorious Medical Technologies, 24 Raul Wallenberg St., Tel-Aviv, Israel.
Friedrich KöhlerDepartment of Cardiology and Angiology at Campus Mitte, Charité - Universitätsmedizin Berlin, Centre for Cardiovascular Telemedicine, Berlin, Germany.
William T AbrahamDivision of Cardiovascular Medicine, The Ohio State University, 473 West 12th Ave., Columbus, OH, 43210, USA.
David MeerkinDepartment of Cardiology, Shaare Zedek Medical Center, Jerusalem, Israel.
Charité - Universitätsmedizin Berlin · DEOnze Lieve Vrouwziekenhuis Hospital · BEShaare Zedek Medical Center · ILTel Aviv University · ILThe Ohio State University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The V-LAP™ measures left atrial pressure (LAP) and enables bi-directional communications with an external unit, designed to monitor heart failure patients. We hereby describe the pre-clinical experience. Following an ex vivo phase, the system was implanted at the interatrial septum of 10 ovine subjects. LAP readouts were compared with pulmonary capillary wedge pressure (PCWP) at index procedure and 1, 2 and 3-6 months after the implantation, at rest and after volume loading. Histopathology assessment (n = 8) was performed up to 50 weeks post procedure. Procedural success was 100%. Measurements showed a mean difference of 0.19 ± 2.51 mmHg. During this period, correlation of V-LAP™ with PCWP was excellent (R

Indexed as

Atrial Function, LeftAtrial PressureTransducers, PressureAnimalsEquipment DesignFeasibility StudiesHeart FailureHumansMaterials TestingModels, AnimalPredictive Value of TestsPulmonary Wedge PressureReproducibility of ResultsSheep, DomesticSus scrofaTelemedicineHeart failure exacerbationHemodynamicsLeft atrial pressureTelemonitoring

Identifiers

PMID30604310
OpenAlexW2906776345

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.