Evidence map›Paper›PMID 30603214›Full record

ArticleBiomedical engineering letters2018

A novel hinged ankle foot orthosis for gait performance in chronic hemiplegic stroke survivors: a feasibility study.

Se-Han Lee, ChangMin Choi, DongGeon Lee, SeungHoo Lee, SunHae Song, SeungHyeon Pyo, SoungKyun Hong, GyuChang Lee

Open access · bronzeAbstract read
In one paragraph

Article in Biomedical engineering letters, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.6field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 8 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Se-Han Lee1Department of Mechanical Engineering, Kyungnam University, Changwon, Republic of Korea.
ChangMin Choi2Department of Advanced Engineering, Graduate School of Kyungnam University, Changwon, Republic of Korea.
DongGeon Lee3Department of Physical Therapy, Graduate School of Kyungnam University, Changwon, Republic of Korea.
SeungHoo Lee3Department of Physical Therapy, Graduate School of Kyungnam University, Changwon, Republic of Korea.
SunHae Song3Department of Physical Therapy, Graduate School of Kyungnam University, Changwon, Republic of Korea.
SeungHyeon Pyo3Department of Physical Therapy, Graduate School of Kyungnam University, Changwon, Republic of Korea.
SoungKyun Hong3Department of Physical Therapy, Graduate School of Kyungnam University, Changwon, Republic of Korea.
GyuChang Lee4Department of Physical Therapy, Kyungnam University, 7 Kyungnamdaehak-ro, Masanhappo-gu, Changwon, Gyeongsangnam-do 51767 Republic of Korea.ORCID 0000-0001-6404-203X
Kyungnam University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Stroke survivors with gait disturbances may use ankle foot orthoses (AFOs). However, most AFOs come in one-piece styles, which make it difficult for spasticity-affected stroke survivors to don. AFOs are also limited since they do not properly prevent ankle joint for foot drop by itself. Therefore, the present study developed a novel hinged AFO by adding a locking device to a hinged joint. We then tested its feasibility in 9 hemiplegic stroke survivors by investigating temporal-spatial gait parameters using the GAITRite in the following 3 conditions: no AFO, traditional AFO, and novel hinged AFO. There was no significant difference in spatiotemporal gait parameters among the different conditions. There were greater decreases in gait velocity, cadence, step length, and stride length in the novel hinged AFO group than in the no AFO and traditional AFO groups. This novel hinged AFO was developed to prevent foot drop. However, the AFO did not show significant differences in gait parameters because it consists of metal with extra weight and volume. Functionally, it prevented foot drop. It also improved convenience by its releasable design. Thus, further studies are needed to develop an AFO that improves gait and is convenient to use for hemiplegic stroke survivors.

Indexed as

Ankle foot orthosisGaitHemiplegic stroke survivors

Identifiers

PMID30603214
PMCPMC6208543
OpenAlexW2806146671

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.