Evidence map›Paper›PMID 30603182›Full record

ArticleBiomedical engineering letters2017

Dielectrophoretic force measurement of red blood cells exposed to oxidative stress using optical tweezers and a microfluidic chip.

Hee-Jae Jeon, Hyungbeen Lee, Dae Sung Yoon, Beop-Min Kim

Open access · bronzeAbstract read
In one paragraph

Article in Biomedical engineering letters, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
0.9field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 22 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Assessment of stored red blood cells through lab-on-a-chip technologies for precision transfusion medicine.Proceedings of the National Academy of Sciences of the United States of America · 2023
    Article
  10. Article
  11. Review
  12. Dielectrophoretic separation of blood cells.Biomedical microdevices · 2022
    Review
  13. Review
  14. Article
  15. Article
  16. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Hee-Jae Jeon1School of Biomedical Engineering, Korea University, Seongbuk-gu, Seoul, 02841 Korea.
Hyungbeen Lee3Department of Biomedical Engineering, Yonsei University, Wonju, 26493 South Korea.
Dae Sung Yoon1School of Biomedical Engineering, Korea University, Seongbuk-gu, Seoul, 02841 Korea.ORCID 0000-0002-6447-2862
Beop-Min Kim1School of Biomedical Engineering, Korea University, Seongbuk-gu, Seoul, 02841 Korea.
Korea University · KRYonsei University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Red blood cell (RBC) dysfunction is often associated with a pathological intervention, and it has been proposed as a critical risk factor for certain lethal diseases. Examining the cell viability of RBCs under various physiological conditions is essential and of importance for precise diagnosis and drug discovery in the field of medicine and pharmacy. In this paper, we report a new analytical method that employs dielectrophoretic (DEP) force measurements in absolute units to assess the viability, and potentially the functionality of RBCs. We precisely quantify the frequency-dependent DEP forces of the RBCs by using a micro-electrode embedded chip combined with optical tweezers. DEP characteristics are known to be well-correlated with the viability of biological cells, and DEP forces are measured in both fresh and long-term stored RBCs to investigate the effect that the storage period has on the cell viability. Moreover, we investigate the DEP behavior of RBCs when exposed to oxidative stress and verify whether EDTA protects the RBCs from an oxidant. From the experiments, it is found that the fresh RBCs without oxidative stress display very high DEP forces over the entire frequency range, exhibiting two cutoff frequencies. However, both the RBCs stored for the long-term period and exposed to oxidative stress reveals that there exist no significant DEP forces over the frequency range. The results indicate that the DEP forces can serve as a useful parameter to verify whether the RBCs in certain blood are fresh and not exposed to oxidative stress. Therefore, it is believed that our system can be applied to a diagnostic system to monitor the cell viability of the RBCs or other types of cells.

Indexed as

DEP measurementEDTAOxidative stressProtective effectRed blood cell

Identifiers

PMID30603182
PMCPMC6208507
OpenAlexW2735947735

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.