Evidence map›Paper›PMID 30597967›Full record

ArticleNanomaterials (Basel, Switzerland)2018

First Generation Amperometric Biosensing of Galactose with Xerogel-Carbon Nanotube Layer-By-Layer Assemblies.

Najwa Labban, Mulugeta B Wayu, Ciara M Steele, Tess S Munoz, Julie A Pollock, William S Case, Michael C Leopold

Open access · goldAbstract read
In one paragraph

Article in Nanomaterials (Basel, Switzerland), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
1.6field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 20 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Najwa LabbanDepartment of Chemistry, 138 UR Drive, Gottwald Center for the Sciences, University of Richmond, Richmond, VA 23173, USA. najwa.labban@richmond.edu.
Mulugeta B WayuDepartment of Chemistry, 138 UR Drive, Gottwald Center for the Sciences, University of Richmond, Richmond, VA 23173, USA. mwayu@richmond.edu.
Ciara M SteeleDepartment of Biology, Chemistry, and Physics, Converse College, Spartanburg, SC 29302, USA. cmsteele001@converse.edu.
Tess S MunozDepartment of Chemistry, 138 UR Drive, Gottwald Center for the Sciences, University of Richmond, Richmond, VA 23173, USA. tess.munoz@richmond.edu.
Julie A PollockDepartment of Chemistry, 138 UR Drive, Gottwald Center for the Sciences, University of Richmond, Richmond, VA 23173, USA. jpollock@richmond.edu.
William S CaseDepartment of Biology, Chemistry, and Physics, Converse College, Spartanburg, SC 29302, USA. will.case@converse.edu.
Michael C LeopoldDepartment of Chemistry, 138 UR Drive, Gottwald Center for the Sciences, University of Richmond, Richmond, VA 23173, USA. mleopold@richmond.edu.
University of Richmond · USConverse College · US

Funding

Arnold and Mabel Beckman Foundation N/ACamille and Henry Dreyfus Foundation N/ACommonwealth Health Research Board N/ANational Institutes of Health P20GM103499 - SC INBRENational Science Foundation CHE-1401593
6 · The paper itself

Abstract

A first-generation amperometric galactose biosensor has been systematically developed utilizing layer-by-layer (LbL) construction of xerogels, polymers, and carbon nanotubes toward a greater fundamental understanding of sensor design with these materials and the potential development of a more efficient galactosemia diagnostic tool for clinical application. The effect of several parameters (xerogel silane precursor, buffer pH, enzyme concentration, drying time and the inclusion of a polyurethane (PU) outer layer) on galactose sensitivity were investigated with the critical nature of xerogel selection being demonstrated. Xerogels formed from silanes with medium, aliphatic side chains were shown to exhibit significant enhancements in sensitivity with the addition of PU due to decreased enzyme leaching. Semi-permeable membranes of diaminobenzene and resorcinol copolymer and Nafion were used for selective discrimination against interferent species and the accompanying loss of sensitivity with adding layers was countered using functionalized, single-walled carbon nanotubes (CNTs). Optimized sensor performance included effective galactose sensitivity (0.037 μA/mM) across a useful diagnostic concentration range (0.5 mM to 7 mM), fast response time (~30 s), and low limits of detection (~80 μM) comparable to literature reports on galactose sensors. Additional modification with anionic polymer layers and/or nanoparticles allowed for galactose detection in blood serum samples and additional selectivity effectiveness.

Indexed as

1st generation biosensoramperometric sensorcarbon nanotubegalactosegalactosemiagalactose oxidasexerogel

Identifiers

PMID30597967
PMCPMC6359589
OpenAlexW2907051812

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.