Evidence map›Paper›PMID 30596807›Full record

Trial reportPloS one2018

Comparison of two column agglutination tests for red blood cell antibody testing.

Jonas Sawierucha, Marion Posset, Viola Hähnel, Christian L Johnson, James A Hutchinson, Norbert Ahrens

Abstract readClinical TrialComparative Study
In one paragraph

Trial report in PloS one, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jonas SawieruchaInstitute for Clinical Chemistry and Laboratory Medicine, Transfusion Medicine, University Hospital Regensburg, Regensburg, Germany.
Marion PossetInstitute for Clinical Chemistry and Laboratory Medicine, Transfusion Medicine, University Hospital Regensburg, Regensburg, Germany.
Viola HähnelInstitute for Clinical Chemistry and Laboratory Medicine, Transfusion Medicine, University Hospital Regensburg, Regensburg, Germany.
Christian L JohnsonInstitute for Clinical Chemistry and Laboratory Medicine, Transfusion Medicine, University Hospital Regensburg, Regensburg, Germany.
James A HutchinsonDepartment of Surgery, University Hospital Regensburg, Regensburg, Germany.ORCID 0000-0002-1199-4210
Norbert AhrensInstitute for Clinical Chemistry and Laboratory Medicine, Transfusion Medicine, University Hospital Regensburg, Regensburg, Germany.ORCID 0000-0002-4680-2688

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSeveral sensitive methods are available for red blood cell (RBC) antibody screening. Among these, gel and glass card systems have demonstrated comparably good performance in retrospective studies and are widely used in routine patient diagnostics, but their performance in prospective studies has not been sufficiently characterised. PATIENTS AND

methodsGel card (Bio-Rad DiaMed) and glass bead-based (Ortho Clinical Diagnostics) column agglutination technologies were used to screen for antibodies prospectively (group A) and for antibody identification in stored and fresh samples known to contain RBC antibodies retrospectively (group B). Untreated reagent RBCs and either papain-treated (Bio-Rad) or ficin-treated panel C cells (Ortho) were used for antibody identification.

resultsRBC-reactive antibodies were detected in 22 of 1000 group A samples, three of which tested positive only by gel card agglutination, and four only by glass bead agglutination (including one false positive each). Group B comprised 202 sera with known antibodies: 33 of these samples contained 36 antibodies detected only by gel card agglutination, whereas 9 samples contained antibodies detectable only by glass bead-based agglutination. Discrepancies mostly involved weak antibodies reactive by enzyme only. Two sera contained antibody mixtures that neither system detected completely. Of note, in antibody differentiation batches one and two, anti-Lua was reactive in 7 of 7 and 1 of 8 samples, respectively.

conclusionBoth column agglutination tests for red cell antibodies had equal sensitivity and specificity with unstored samples. In stored samples, weak and enzyme-only antibodies were more frequently detected with the gel card system.

Indexed as

Agglutination TestsABO Blood-Group SystemErythrocytesFemaleHumansIsoantibodiesMaleABO Blood-Group SystemIsoantibodies

Identifiers

PMID30596807
PMCPMC6312228

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.