ArticleACS applied materials & interfaces2019
Mechanical Properties and Concentrations of Poly(ethylene glycol) in Hydrogels and Brushes Direct the Surface Transport of Staphylococcus aureus.
Article in ACS applied materials & interfaces, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 29 citations in OpenAlex.
- Ancestry-linked IL-10 signaling and macrophage activation modulate fibroblast responses to oxidative stress in a PEG-based microphysiological system.npj biomedical innovations · 2026Article
- Polydimethylsiloxane gel thickness and stiffness affect the initial adhesion ofRSC applied polymers · 2026Article
- Stiffness and Oligomer Content Affect the Initial Adhesion ofACS applied materials & interfaces · 2023Article
- The Use of Hydrogels for the Treatment of Bone Osteosarcoma via Localized Drug-Delivery and Tissue Regeneration: A Narrative Review.Gels (Basel, Switzerland) · 2023Review
- Glucose biosensors based on Michael addition crosslinked poly(ethylene glycol) hydrogels with chemo-optical sensing microdomains.Journal of materials chemistry. B · 2023Article
- Article
- Article
- Motility Increases the Numbers and Durations of Cell-Surface Engagements forACS applied materials & interfaces · 2022Article
- Self-Assembling Polypeptide Hydrogels as a Platform to Recapitulate the Tumor Microenvironment.Cancers · 2021Article
- Article
- Generation of Photopolymerized Microparticles Based on PEGDA Using Microfluidic Devices. Part 1. Initial Gelation Time and Mechanical Properties of the Material.Micromachines · 2021Article
- Rapid Electrostatic Capture of Rod-Shaped Particles on Planar Surfaces: Standing up to Shear.Langmuir : the ACS journal of surfaces and colloids · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
Abstract
Surface-associated transport of flowing bacteria, including cell rolling, is a mechanism for otherwise immobile bacteria to migrate on surfaces and could be associated with biofilm formation or the spread of infection. This work demonstrates how the moduli and/or local polymer concentration play critical roles in sustaining contact, dynamic adhesion, and transport of bacterial cells along a hydrogel or hydrated brush surface. In particular, stiffer more concentrated hydrogels and brushes maintained the greatest dynamic contact, still allowing cells to travel along the surface in flow. This study addressed how the mechanical properties, molecular architectures, and thicknesses of minimally adhesive poly(ethylene glycol) (PEG)-based coatings influence the flow-driven surface motion of Staphylococcus aureus MS2 cells. Three protein-repellant PEG-dimethylacrylate hydrogel films (∼100 μm thick) and two protein-repellant PEG brushes (8-16 nm thick) were sufficiently fouling-resistant to prevent the accumulation of flowing bacteria. However, the rolling or hopping-like motions of gently flowing S. aureus cells along the surfaces were specific to the particular hydrogel or brush, distinguishing these coatings in terms of their mechanical properties (with moduli from 2 to 1300 kPa) or local PEG concentrations (in the range 10-50% PEG). On the stiffer hydrogel coatings having higher PEG concentrations, S. aureus exhibited long runs of surface rolling, 20-50 μm in length, an increased tendency of cells to repeatedly return to some surfaces after rolling and escaping, and relatively long integrated contact times. By contrast, on the softer more dilute hydrogels, bacteria tended to encounter the surface for brief periods before escaping without return. The dynamic adhesion and motion signatures of the cells on the two brushes were bracketed by those on the soft and stiff hydrogels, demonstrating that PEG coating thickness was not important in these studies where the vertically oriented surfaces minimized the impact of gravitational forces. Control studies with similarly sized poly(ethylene oxide)-coated rigid spherical microparticles, that also did not arrest on the PEG coatings, established that the bacterial skipping and rolling signatures were specific to the S. aureus cells and not simply diffusive. Dynamic adhesion of the S. aureus cells on the PEG hydrogel surfaces correlated well with quiescent 24 h adhesion studies in the literature, despite the orientation of the flow studies that eliminated the influence of gravity on bacteria-coating normal forces.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.