ArticleJournal of medical biochemistry2018

A Preliminary Proposal for Quality Control Assessment and Harmonization of Leukocytes Morphology-structural Parameters (cell Population Data Parameters).

Michela Seghezzi, Sabrina Buoro, Giulia Previtali, Valentina Moioli, Barbara Manenti, Ramon Simon-Lopez, Cosimo Ottomano, Giuseppe Lippi

Abstract read
In one paragraph

Article in Journal of medical biochemistry, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Observational
  7. Article
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Michela SeghezziClinical Chemistry Laboratory, Hospital Papa Giovanni XXIII, Bergamo, Italy.
Sabrina BuoroClinical Chemistry Laboratory, Hospital Papa Giovanni XXIII, Bergamo, Italy.
Giulia PrevitaliClinical Chemistry Laboratory, Hospital Papa Giovanni XXIII, Bergamo, Italy.
Valentina MoioliClinical Chemistry Laboratory, Hospital Papa Giovanni XXIII, Bergamo, Italy.
Barbara ManentiClinical Chemistry Laboratory, Hospital Papa Giovanni XXIII, Bergamo, Italy.
Ramon Simon-LopezSysmex Corporation, Chuo-ku Japan.
Cosimo OttomanoSynlab, Castenedolo, Castenedolo Italy.
Giuseppe LippiSection of Clinical Biochemistry, University of Verona, Verona, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe cell population data (CPD) measured by Sysmex XN-9000 can be used for screening many hematological and non-hematological disorders. Since little information is available on harmonization of CPD among different instrumentation and clinical laboratories, this study aimed at assessing the current degree of CPD harmonization between separate Sysmex XN modules allocated to the same laboratory.

methodsA total number of 78291 data were used for verification of within-run imprecision, analyzers harmonization, reference ranges and assessment of blood sample stability of CPD parameters, including results of daily quality control testing and those generated in samples collected from blood donors and healthy volunteers.

resultsWithin-run imprecision of CPD parameters ranged between 0.4 and 14.1%. Good agreement was found among five different XN-modules, especially when values were adjusted after calculation of instrument-specific alignment factors. The bias of all parameters remained always lower than the reference change values in samples stored for up to 8 hours, regardless of storage temperature.

conclusionsThe imprecision of CPD parameters was acceptable, except for those reflecting the dispersion of cellular clusters. Due to the lack of reference control materials, we showed that the use of data generated on a large number of normal routine samples (i.e., a Moving Average population) may be a reliable approach for testing analyzers harmonization. Nevertheless, availability of both calibration and quality control materials for these parameters is highly advisable in the future. We finally showed that whole blood samples may be stable for up to 2-4 hours for most CPD parameters.

Indexed as

cell population dataquality controlreference rangestabilitywithin-run imprecision

Identifiers

PMID30584409
PMCPMC6298477

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.