Evidence map›Paper›PMID 30581843›Full record

ArticleBioMed research international2018

EIT Imaging of Intracranial Hemorrhage in Rabbit Models Is Influenced by the Intactness of Cranium.

Meng Dai, Xue-Chao Liu, Hao-Ting Li, Can-Hua Xu, Bin Yang, Hang Wang, Xue-Tao Shi, Xiu-Zhen Dong, Feng Fu

Abstract read
In one paragraph

Article in BioMed research international, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. The Research Progress of Electrical Impedance Tomography for Lung Monitoring.Frontiers in bioengineering and biotechnology · 2021
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Meng DaiSchool of Biomedical Engineering, Air Force Military Medical University, Xi'an, China.
Xue-Chao LiuSchool of Biomedical Engineering, Air Force Military Medical University, Xi'an, China.
Hao-Ting LiSchool of Biomedical Engineering, Air Force Military Medical University, Xi'an, China.
Can-Hua XuSchool of Biomedical Engineering, Air Force Military Medical University, Xi'an, China.ORCID 0000-0003-0728-3544
Bin YangSchool of Biomedical Engineering, Air Force Military Medical University, Xi'an, China.
Hang WangSchool of Aerospace Medicine, Air Force Military Medical University, Xi'an, China.
Xue-Tao ShiSchool of Biomedical Engineering, Air Force Military Medical University, Xi'an, China.
Xiu-Zhen DongSchool of Biomedical Engineering, Air Force Military Medical University, Xi'an, China.ORCID 0000-0002-6575-4204
Feng FuSchool of Biomedical Engineering, Air Force Military Medical University, Xi'an, China.ORCID 0000-0003-0547-7601

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Electrical impedance tomography (EIT) has been shown to be a promising, bedside imaging method to monitor the progression of intracranial hemorrhage (ICH). However, the observed impedance changes within brain related to ICH differed among groups, and we hypothesized that the cranium intactness (open or closed) may be the one of potential reasons leading to the difference. Therefore, the aim of this study was to investigate this effect of open or closed cranium on impedance changes within brain in the rabbit ICH model. In this study, we first established the ICH model in 12 rabbits with the open cranium and in 12 rabbits with the closed cranium. Simultaneously, EIT measurements on the rabbits' heads were performed to record the impedance changes caused by injecting the autologous nonheparinized blood into cerebral parenchyma. Finally, the regional impedance changes on EIT images and the whole impedance changes were analyzed. It was surprisingly found that when the cranium was open, the impedance of the area where the blood was injected, as well as the whole brain impedance, decreased with the amount of blood being injected; when the cranium was closed, while the impedance of the area where blood was not injected continued to increase, the impedance of the area where blood was injected decreased within 20s of the blood being injected and then remained almost unchanged, and the whole brain impedance had a small fall and then notably increased. The results have validated that the cranium completeness (open or closed) has influences on impedance changes within brain when using EIT to monitor ICH. In future study on application of EIT to monitor ICH, the cranium completeness should be taken into account for establishing an ICH model and analyzing the corresponding EIT results.

Indexed as

AnimalsBrainDisease Models, AnimalElectric ImpedanceElectrodesIntracranial HemorrhagesMonitoring, PhysiologicRabbitsSkullTomography

Identifiers

PMID30581843
PMCPMC6276518

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.