ArticleWorld journal of surgical oncology2018
Robotic total gastrectomy with π-shaped esophagojejunostomy using a linear stapler as a novel technique.
Article in World journal of surgical oncology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 13 citations in OpenAlex.
- Comparative analysis of overlap and π-shaped esophagojejunostomy in totally laparoscopic total gastrectomy with propensity score matching.Updates in surgery · 2026Article
- Minimally invasive lymphadenectomy for gastric cancer: Could the robotic approach provide any benefits than laparoscopy?World journal of gastrointestinal oncology · 2025Review
- Technical variety of anastomotic techniques used in proximal gastrectomy with double-tract-reconstruction - a narrative review.Langenbeck's archives of surgery · 2024Review
- ModifiedThe Journal of international medical research · 2022Article
- Risk Factors for the Severity of Complications in Minimally Invasive Total Gastrectomy for Gastric Cancer: a Retrospective Cohort Study.Journal of gastric cancer · 2021Article
- A novel method for π-shaped esophagojejunostomy and double-tract reconstruction (DTR) as an alternative in totally laparoscopic or robotic proximal gastrectomy for treating upper third proximal early gastric cancer.Updates in surgery · 2021Article
- Robot-assisted laparoscopic subtotal gastrectomy for early-stage gastric cancer: Case series of initial experience.Annals of medicine and surgery (2012) · 2021Article
- Short- and long-term outcomes of totally robotic versus robotic-assisted radical distal gastrectomy for advanced gastric cancer: a mono-institution retrospective study.World journal of surgical oncology · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
Abstract
objectiveTo evaluate the intraoperative and short-term postoperative outcomes of a novel robotic intracorporeal π-shaped esophagojejunostomy (EJS) after D2 total gastrectomy (TG) using the Da Vinci robotic surgical system for intracorporeal anastomosis after TG.
backgroundIntracorporeal π-shaped EJS, using a linear stapler, was recently reported for laparoscopic total gastrectomy in patients with gastric cancer. However, robotic intracorporeal π-shaped EJS using a linear stapler has not been reported. This report aimed to describe the use of a novel technique for π-shaped EJS using the Da Vinci robotic system.
methodsRobotic intracorporeal π-shaped esophagojejunostomy after total gastrectomy was performed in 11 consecutive patients diagnosed with early gastric cancer, and their perioperative outcomes were analyzed.
resultsAll the operations were successful without conversion to open or laparoscopic surgery and postoperative complications. The total number of patients was 11 (7 males and 4 females). The mean age of the patients was 63.36 ± 10.56 years old. Seven patients were diagnosed with cardia cancer, 3 patients were diagnosed with gastric body cancer, and 1 patient was diagnosed with gastric antrum cancer. The patients' mean proximal resection margin was 3.18 ± 1.17 cm, the distal resection margin was 6.18 ± 1.40 cm, the mean length of the incision was 4.55 ± 0.69 cm, the mean operative time was 287.27 ± 30.69 min, the mean day of first flatus was 3.27 ± 0.79 days, the mean day of the start of diet was 2.91 ± 0.94 days, the mean postoperative hospital stay was 11.45 ± 5.13 days, and the mean operative blood loss was 47.27 ± 31.33 ml. No complications were observed during anastomosis, and the median anastomosis time was 19.5 min. The mean number of lymph node dissections was 17.91 ± 4.59, the mean number of positive lymph nodes was 0.45 ± 0.69, all patients were diagnosed with stage I-II gastric cancer, and the mean maximum diameter of the tumor was 2.67 ± 1.30 cm. All the patients had a smooth hospital discharge.
conclusionA novel robotic gastrectomy with intracorporeal π-shaped EJS for esophagojejunal anastomosis described and shows acceptable resulted. This technique has the potential to offer better short-term surgical outcomes and overcomes the drawbacks of laparoscopy with a decreased risk of complications during and after surgery.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.