ArticleContraception2019
One-year continuation of postpartum intrauterine contraceptive device: findings from a retrospective cohort study in India.
Article in Contraception, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 2 syntheses or guidelines pooled it.
- Utilisation, effectiveness, and safety of immediate postpartum intrauterine device insertion: a systematic literature review.BMJ sexual & reproductive health · 2023Pooled it
- Expulsion of intrauterine devices after postpartum placement by timing of placement, delivery type, and intrauterine device type: a systematic review and meta-analysis.American journal of obstetrics and gynecology · 2020Pooled it
- One-year continuation of postpartum intrauterine contraceptive device: Findings from a prospective cohort study in India.PloS one · 2024Article
- Barriers and Enablers Influencing Women's Adoption and Continuation of Vaginally Inserted Contraceptive Methods: A Literature Review.Studies in family planning · 2022Review
- Immediate postpartum intrauterine contraceptive device utilization and influencing factors in Addis Ababa public hospitals: a cross-sectional study.Contraception and reproductive medicine · 2021Article
- A one-year cohort study of complications, continuation, and failure rates of postpartum TCu380A in Tanzania.Reproductive health · 2020Article
- Exploring reasons for discontinuing use of immediate post-partum intrauterine device in Nepal: a qualitative study.Reproductive health · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveTo evaluate outcomes of a national postpartum (within 48 h of delivery) copper intrauterine device placement (PPCuIUD) program in six "high-focus states" with high unmet family planning need in India. STUDY
designWe identified high-volume district hospitals that provided PPCuIUD in six (Bihar, Jharkhand, Uttar Pradesh, Uttarakhand, Madhya Pradesh and Chhattisgarh) Indian states (two per state). Each selected hospital maintained a list of PPCuIUD acceptors with contact phone numbers. We randomly selected 100 women at each site for inclusion in a telephone survey of IUD outcomes at 1 year. Questions regarded IUD expulsion, discontinuation because of symptoms (e.g., pain, bleeding, discharge), discontinuation for other reasons and use of alternative contraception if discontinuation reported.
resultsWe could contact 844 of the 1200 randomly selected women, of whom 673 (79.7%) had postplacental insertion (within 10 min of delivery), while 171 (20.3%) had an early postpartum insertion (between 10 min to 48 h after delivery). Of those contacted, 530 women (62.8%) reported continuing with the method beyond 1 year, 63 (7.5%) reported having an expulsion, 163 (19.3%) reported having removals for associated side effects (bleeding, pain and discharge), and 88 (10.4%) reported having removals for other reasons. After removal or expulsion, almost half of the women (46.5%) did not switch to any other modern contraceptive method.
conclusionPPCuIUD continuation rate at 1 year was 62.8%. Most removals within 1 year were due to associated side effects. Almost half of the women discontinuing PPCuIUD did not switch to an alternative modern contraceptive method. IMPLICATIONS: The 1-year continuation rate of PPCuIUD achieved through a large-scale national program in India is satisfactory. The program though needs to address the low uptake of other modern contraceptive methods after discontinuation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.