ArticlePloS one2018
The Laplace Project: An integrated suite for preparing and transferring atom probe samples under cryogenic and UHV conditions.
Article in PloS one, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
18 citing papers in PubMed.
- Article
- A workflow for correlativeNanoscale horizons · 2025Article
- Scalable substrate development for aqueous sample preparation for atom probe tomography.Journal of microscopy · 2025Article
- Grain Boundaries Control Lithiation of Solid Solution Substrates in Lithium Metal Batteries.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025Article
- The Fate of Water in Hydrogen-Based Iron Oxide Reduction.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2023Article
- Electron microscope loading and in situ nanoindentation of water ice at cryogenic temperatures.PloS one · 2023Article
- Deuterium Distribution in Fe/V Multi-Layered Films.Molecules (Basel, Switzerland) · 2022Article
- Nanoscale analysis of frozen honey by atom probe tomography.Scientific reports · 2022Article
- Understanding the Degradation of a Model Si Anode in a Li-Ion Battery at the Atomic Scale.The journal of physical chemistry letters · 2022Article
- Atom probe analysis of electrode materials for Li-ion batteries: challenges and ways forward.Journal of materials chemistry. A · 2022Article
- Article
- Laser-equipped gas reaction chamber for probing environmentally sensitive materials at near atomic scale.PloS one · 2022Article
- Hydrogen and deuterium charging of lifted-out specimens for atom probe tomography.Open research Europe · 2021Article
- Atom probe tomography.Nature reviews. Methods primers · 2021Article
- A versatile cryo-transfer system, connecting cryogenic focused ion beam sample preparation to atom probe microscopy.PloS one · 2021Article
- Enabling near-atomic-scale analysis of frozen water.Science advances · 2020Article
- New frontiers in atom probe tomography: a review of research enabled by cryo and/or vacuum transfer systems.Materials today. Advances · 2020Article
- Ti and its alloys as examples of cryogenic focused ion beam milling of environmentally-sensitive materials.Nature communications · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
16 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
We present sample transfer instrumentation and integrated protocols for the preparation and atom probe characterization of environmentally-sensitive materials. Ultra-high vacuum cryogenic suitcases allow specimen transfer between preparation, processing and several imaging platforms without exposure to atmospheric contamination. For expedient transfers, we installed a fast-docking station equipped with a cryogenic pump upon three systems; two atom probes, a scanning electron microscope / Xe-plasma focused ion beam and a N2-atmosphere glovebox. We also installed a plasma FIB with a solid-state cooling stage to reduce beam damage and contamination, through reducing chemical activity and with the cryogenic components as passive cryogenic traps. We demonstrate the efficacy of the new laboratory protocols by the successful preparation and transfer of two highly contamination- and temperature-sensitive samples-water and ice. Analysing pure magnesium atom probe data, we show that surface oxidation can be effectively suppressed using an entirely cryogenic protocol (during specimen preparation and during transfer). Starting with the cryogenically-cooled plasma FIB, we also prepared and transferred frozen ice samples while avoiding significant melting or sublimation, suggesting that we may be able to measure the nanostructure of other normally-liquid or soft materials. Isolated cryogenic protocols within the N2 glove box demonstrate the absence of ice condensation suggesting that environmental control can commence from fabrication until atom probe analysis.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials