Evidence map›Paper›PMID 30572931›Full record

ArticleMilitary Medical Research2018

Military trainees can accurately measure optic nerve sheath diameter after a brief training session.

Joseph Betcher, Torben K Becker, Peter Stoyanoff, Jim Cranford, Nik Theyyunni

Abstract read
In one paragraph

Article in Military Medical Research, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Observational
  2. Article
  3. Advancements in Non-Invasive Intracranial Pressure Monitoring via Optic Nerve Sheath Diameter Measurement.Medical science monitor : international medical journal of experimental and clinical research · 2025
    Review
  4. Article
  5. Review
  6. Article
  7. Article
  8. Optic Nerve Sheath Ultrasound for the Detection and Monitoring of Raised Intracranial Pressure in Tuberculous Meningitis.Clinical infectious diseases : an official publication of the Infectious Diseases Society of America · 2021
    Article
  9. Review
  10. Review
  11. Review
  12. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors.

Joseph BetcherDepartment of Emergency Medicine, Mercy Health Muskegon, 1500 E Sherman Blvd, Muskegon, MI, 49444, USA. joebetcher@gmail.com.ORCID 0000-0003-4443-3820
Torben K BeckerDepartment of Critical Care Medicine, University of Pittsburgh Medical Center, 200 Lothrop St, Pittsburgh, PA, 15213, USA.
Peter StoyanoffDepartment of Emergency Medicine, Hurley Hospital, 1 Hurley Plaza, Flint, MI, 48503, USA.
Jim CranfordDepartment of Psychiatry, University of Michigan, 1500 E Medical Center, Ann Arbor, MI, 48109, USA.
Nik TheyyunniDepartment of Emergency Medicine, University of Michigan, 1500 E Medical Center, Ann Arbor, MI, 48109, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIdentification of elevated intracranial pressure is important following traumatic brain injury. We assessed the feasibility of educating military trainees on accurately obtaining optic nerve sheath diameter measurements using a brief didactic and hands-on training session. Optic nerve sheath diameter is a noninvasive surrogate marker for elevated intracranial pressure, and may be of value in remote military operations, where rapid triage decisions must be made without access to advanced medical equipment.

methodsMilitary trainees with minimal ultrasound experience were given a 5-min didactic presentation on optic nerve sheath diameter ultrasound. Trainees practiced optic nerve sheath diameter measurements guided by emergency physician ultrasound experts. Trainees then measured the optic nerve sheath diameter on normal volunteers. Following this, a trained physician measured the optic nerve sheath diameter on the same volunteer as a criterion standard. An average of three measurements was taken.

resultsTwenty-three military trainees were enrolled. A mixed design ANOVA was used to compare measurements by trainees to those of physicians, with a mean difference of - 0.6 mm (P = 0.76). A Bland-Altman analysis showed that the degree of bias in optic nerve sheath diameter measures provided by trainees was very small: d = - 0.004 for the right eye and d = - 0.007 for the left eye.

conclusionThis study demonstrates that optic nerve sheath diameter measurement can be accurately performed by novice ultrasonographers after a brief training session. If validated, point-of-care optic nerve sheath diameter measurement could impact the triage of injured patients in remote areas.

Indexed as

Clinical CompetenceCurriculumHumansIntracranial HypertensionMilitary PersonnelOptic NervePoint-of-Care TestingSurveys and QuestionnairesTeachingUltrasonographyEducationIntracranial pressureMilitaryOptic nerve sheath diameterUltrasound

Identifiers

PMID30572931
PMCPMC6300875

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.