Evidence map›Paper›PMID 30571620›Full record

ArticleIEEE transactions on ultrasonics, ferroelectrics, and frequency control2019

Analysis and Design of High-Frequency 1-D CMUT Imaging Arrays in Noncollapsed Mode.

Evren Fatih Arkan, F Levent Degertekin

Abstract read
In one paragraph

Article in IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. cMUT technology developments.Zeitschrift fur medizinische Physik · 2023
    Review
  5. Review
  6. Analysis of Negative Capacitance-Based Broadband Impedance Matching for CMUTs.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2021
    Article
  7. Article
  8. Highly Integrated Guidewire Ultrasound Imaging System-on-a-Chip.IEEE journal of solid-state circuits · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Evren Fatih Arkan
F Levent Degertekin

Funding

Feasibility of folded ultrasound arrays for high resolution 3-D imaging intracardiac echography cathetersR21EB024253 · NIBIB · GEORGIA INSTITUTE OF TECHNOLOGY · PI DEGERTEKIN, F. LEVENT · 2017 to 2018
$404k
Intravascular Ultrasound Imaging Guidewire with Wireless ReadoutR21EB017365 · NIBIB · GEORGIA INSTITUTE OF TECHNOLOGY · PI DEGERTEKIN, F. LEVENT, GHOVANLOO, MAYSAM · 2014 to 2015
$388k
NIBIB NIH HHS R21 EB017365NIBIB NIH HHS R21 EB024253
6 · The paper itself

Abstract

High-frequency ultrasound imaging arrays are important for a broad range of applications, from small animal imaging to photoacoustics. Capacitive micromachined ultrasonic transducer (CMUT) arrays are particularly attractive for these applications as low noise receiver electronics can be integrated for an overall improved performance. In this paper, we present a comprehensive analysis of high-frequency CMUT arrays based on an experimentally verified CMUT array simulation tool. The results obtained on an example, a 40-MHz 1-D CMUT array for intravascular imaging, are used to obtain key design insights and tradeoffs for receive only and pulse-echo imaging. For the receiver side, thermal mechanical current noise, plane wave pressure sensitivity, and pressure noise spectrum are extracted from simulations. Using these parameters, we find that the receiver performance of CMUT arrays can be close to an ideal piston, independent of gap thickness, and applied dc bias, when coupled to low noise electronics with arrays utilizing smaller membranes performing better. For pulse-echo imaging, thermal mechanical current noise limited signal-to-noise ratio is observed to be dependent on the maximum available voltage and gap thickness. In terms of bandwidth, we find that the Bragg resonance of the array, related to the fill factor, is a significant determinant of the high frequency limit and the fluid loaded single membrane resonance determines the lower limit. Based on these results, we present design guidelines requiring only fluid loaded single membrane simulations and membrane pitch to achieve a desired pulse-echo response. We also provide a design example and discuss limitations of the approach.

Indexed as

TransducersAlgorithmsEquipment DesignPhotoacoustic TechniquesUltrasonography

Identifiers

PMID30571620
PMCPMC6415772

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.