ArticleJournal of clinical hypertension (Greenwich, Conn.)2019
A convenient method to verify the accuracy of oscillometric blood pressure monitors by the auscultatory method: A smartphone-based app.
Article in Journal of clinical hypertension (Greenwich, Conn.), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 11 citations in OpenAlex.
- The Post-Marketing Real-World Outpatient Clinical Validation of Electronic Blood Pressure Monitors.Journal of clinical hypertension (Greenwich, Conn.) · 2026Article
- Assessing the strengths and limitations of non-invasive blood pressure measurement.Journal of clinical hypertension (Greenwich, Conn.) · 2023Article
- The Hemodynamic Parameters Values Prediction on the Non-Invasive Hydrocuff Technology Basis with a Neural Network Applying.Sensors (Basel, Switzerland) · 2022Article
- Korotkoff sounds dynamically reflect changes in cardiac function based on deep learning methods.Frontiers in cardiovascular medicine · 2022Review
- Lung Auscultation of Hospitalized Patients with SARS-CoV-2 Pneumonia via a Wireless Stethoscope.International journal of medical sciences · 2021Article
- A convenient method to verify the accuracy of oscillometric blood pressure monitors by the auscultatory method: A smartphone-based app.Journal of clinical hypertension (Greenwich, Conn.) · 2019Article
- How to ensure personalized accuracy in home blood pressure devices: Should we play it by ear?Journal of clinical hypertension (Greenwich, Conn.) · 2019Article
Corrections and comments
- Commented on by
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
It is recommended that oscillometric devices be calibrated by auscultation when first used, but this is difficult in practice. Here, we introduce a smartphone-based technique to verify the accuracy of blood pressure monitors (BPMs). We enrolled 99 consecutive subjects and tested 6 brands of BPMs in this study. During measurements of electronic oscillometric BPMs, Korotkoff sounds were simultaneously collected using a stethoscope head beneath a cuff connected to a smartphone, and an app named Accutension Stetho could then yield an auscultatory BP reading as a reference. Next, differences in BP between the different BPMs and Accutension Stetho were determined. The percentage of BP differences falling within 5, 10, and 15 mm Hg; the mean (MD) value; and the standard deviation (SD) of BP differences and deflation errors were analyzed among all the BPMs. We found that the percentages of SBP differences falling within 5 mm Hg of the 6 BPMs were 80%, 79%, 77%, 72%, 68%, and 63%, in turn. The deflation rates among the 6 BPMs were 2.23, 3.48, 6.10, 2.44, 3.66, and 4.85 mm Hg/beat, respectively. Deflation errors, which were defined as deflation prior to the end of the Korotkoff sounds, existed in 4 BPMs. In conclusion, Accutension Stetho could detect BP differences between oscillometric BPM readings and simultaneous auscultatory readings. Diastolic BP was overestimated when the device deflated prior to the end of the Korotkoff sounds. Using the app, it is possible to evaluate the accuracy of BPMs among the same subjects.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials