A convenient method to verify the accuracy of oscillometric blood pressure monitors by the auscultatory method: A smartphone-based app.

Zhi Zhang, Weichun Xi, Bingjiang Wang, Guang Chu, Fang Wang

Open access · greenAbstract read
In one paragraph

Article in Journal of clinical hypertension (Greenwich, Conn.), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
0.9field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Assessing the strengths and limitations of non-invasive blood pressure measurement.Journal of clinical hypertension (Greenwich, Conn.) · 2023
    Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Zhi ZhangDepartment of Cardiology, Shanghai General Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.
Weichun XiDepartment of Cardiology, Shanghai General Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.
Bingjiang WangDepartment of Cardiology, Huai'an First People's Hospital affiliated with Nanjing Medical University, Huai'an, China.
Guang ChuDepartment of Cardiology, Shanghai General Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.
Fang WangDepartment of Cardiology, Shanghai General Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.ORCID 0000-0003-1872-259X
Shanghai First People's Hospital · CNHuaian First People’s Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

It is recommended that oscillometric devices be calibrated by auscultation when first used, but this is difficult in practice. Here, we introduce a smartphone-based technique to verify the accuracy of blood pressure monitors (BPMs). We enrolled 99 consecutive subjects and tested 6 brands of BPMs in this study. During measurements of electronic oscillometric BPMs, Korotkoff sounds were simultaneously collected using a stethoscope head beneath a cuff connected to a smartphone, and an app named Accutension Stetho could then yield an auscultatory BP reading as a reference. Next, differences in BP between the different BPMs and Accutension Stetho were determined. The percentage of BP differences falling within 5, 10, and 15 mm Hg; the mean (MD) value; and the standard deviation (SD) of BP differences and deflation errors were analyzed among all the BPMs. We found that the percentages of SBP differences falling within 5 mm Hg of the 6 BPMs were 80%, 79%, 77%, 72%, 68%, and 63%, in turn. The deflation rates among the 6 BPMs were 2.23, 3.48, 6.10, 2.44, 3.66, and 4.85 mm Hg/beat, respectively. Deflation errors, which were defined as deflation prior to the end of the Korotkoff sounds, existed in 4 BPMs. In conclusion, Accutension Stetho could detect BP differences between oscillometric BPM readings and simultaneous auscultatory readings. Diastolic BP was overestimated when the device deflated prior to the end of the Korotkoff sounds. Using the app, it is possible to evaluate the accuracy of BPMs among the same subjects.

Indexed as

AdultAgedAged, 80 and overBlood Pressure Monitoring, AmbulatoryBlood Pressure MonitorsCalibrationChinaFemaleHumansMaleMiddle AgedMobile ApplicationsOscillometryYoung Adultauscultatoryblood pressure measurement.blood pressure monitorhypertensionoscillometric sphygmomanometer

Identifiers

PMID30570199
PMCPMC8030511
OpenAlexW2905627129

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.