Evidence map›Paper›PMID 30569422›Full record

ArticleJournal of clinical monitoring and computing2019

Anesthesia depth monitoring using alternative placement of entropy sensors: a prospective study.

David I Vachnadze, Boris A Akselrod, Denis A Guskov, Alevtina V Goncharova

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of clinical monitoring and computing, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. End of year summary 2019: anaesthesia and airway management.Journal of clinical monitoring and computing · 2020
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

David I VachnadzeFSBSI «Petrovsky NRCS», Abrikosovsky, 2, 119991, Moscow, Russia. david1255@yandex.ru.ORCID http://orcid.org/0000-0003-0482-3795
Boris A AkselrodFSBSI «Petrovsky NRCS», Abrikosovsky, 2, 119991, Moscow, Russia.
Denis A GuskovFSBSI «Petrovsky NRCS», Abrikosovsky, 2, 119991, Moscow, Russia.
Alevtina V GoncharovaFSBSI «Petrovsky NRCS», Abrikosovsky, 2, 119991, Moscow, Russia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Spectral entropy is based on analysis of variations in electroencephalography and frontal electromyography, and is a safe and reliable method for anesthesia depth monitoring. However, standard frontal positioning of entropy electrodes in patients undergoing cardiac surgery is sometimes challenging. The present study aimed to compare standard entropy sensor placement with an alternative (infraorbital) site. This prospective study included 20 patients who underwent cardiovascular surgery at the authors' center. Monitoring was performed with standard and alternative entropy electrode positions from patient admission to surgery to transfer to the intensive care unit. Data were recorded every 15 s; all data were analyzed and compared using Bland-Altman, scatter plot with Pearson correlation coefficient, and sensitivity/specificity analyses. Overall, 20,784 pairs of response entropy (RE) and state entropy (SE) indexes were collected. Bland-Altman analysis revealed a mean difference in RE of 0.37 (95% LOA - 7.09, 7.88) and SE 0.69 (95% LOA - 5.95, 7.31); with 3.46% (720/20,784) RE and 3.40% (706/10,790) SE values lying outside of the limits of agreement. Correlation analysis revealed strong positive correlation in both cases: RE, r = 0.983, p < 0.05; SE, r = 0.984; p < 0.05. Sensitivity/specificity analysis revealed 98.1% sensitivity, 93.3% specificity and 97.1% test efficiency for RE, and 99.2%, 95.1% and 98.5% for SE, respectively. Infraorbital entropy sensor placement in patients undergoing cardiovascular surgery is reliable and effective. The strong positive correlation between the two methods of registration enables alternative entropy measurement when frontal placement is not possible.

Indexed as

EntropyAgedAnesthesiaAnesthesia, GeneralCardiac Surgical ProceduresCritical CareElective Surgical ProceduresElectrodesElectromyographyFemaleHumansIntensive Care UnitsMaleMiddle AgedMonitoring, IntraoperativeProspective StudiesAnesthesia depthEntropyNeuromonitoringSpectral entropy

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.