Evidence map›Paper›PMID 30569398›Full record

ArticleMedical & biological engineering & computing2019

M-sequence-coded excitation for magneto-acoustic imaging.

Shunqi Zhang, Ren Ma, Tao Yin, Zhipeng Liu

Abstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Coded Excitation for Ultrasonic Testing: A Review.Sensors (Basel, Switzerland) · 2024
    Review
  2. [Research on magneto-acoustic-electrical tomography method based on liquid metal contrast agent and M sequence coded excitation].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2023
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Shunqi ZhangInstitute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin, China.
Ren MaInstitute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin, China.
Tao YinInstitute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin, China.
Zhipeng LiuInstitute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin, China. lzpeng67@163.com.ORCID http://orcid.org/0000-0001-7434-4402

Funding

National Natural Science Foundation of China 61501523National Natural Science Foundation of China 81772004
6 · The paper itself

Abstract

Magneto-acoustic imaging is a novel functional imaging method to electrical characteristics of tissue. It provides valuable tools for diagnosing early stage tumor and monitoring bioelectrical current. Common single short-pulse excitation limits SNR due to the short-pulse duration and low power of magneto-acoustic signal. In this study, we propose M-sequence-coded excitation and pulse compression approach to improve SNR of magneto-acoustic imaging. Simulations on the magneto-acoustic signal under different bit lengths M-sequence-coded excitation are performed. Experiments on the samples made of pork and graphite slices are done to validate the proposed coded excitation method. The SNR and sidelobe levels were investigated. The results showed when 7, 15, 31, 63, 127 bits M-sequence-coded excitations were applied onto the samples, SNR was improved by 17.4 dB, 24.2 dB, 30.6 dB, 37.6 dB, and 40.1 dB, respectively. For a similar SNR improvement, the total used time under coded excitation can be shortened to 9.4% under the single pulse excitation. The result indicates the M-sequence-coded excitation approach is effective to improve the magneto-acoustic signal SNR and shorten the imaging time. Graphical abstract SNR of the magneto-acoustic signal is significantly improved by the coded excitation than the pulse excitation, the reconstructed image of the front and back boundary of the pork can be seen clearly under the 7, 15, 31, 63, 127 bit M-sequence-coded excitations.

Indexed as

AcousticsSignal Processing, Computer-AssistedComputer SimulationData CompressionElectromagnetic FieldsFinite Element AnalysisGraphiteImage Processing, Computer-AssistedRed MeatSignal-To-Noise RatioGraphiteMagneto-acoustic imagingM-sequence codePulse compressionSignal-to-noise ratio (SNR)

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked