ArticleMagnetic resonance in medicine2019
Rapid dual-RF, dual-echo, 3D ultrashort echo time craniofacial imaging: A feasibility study.
Article in Magnetic resonance in medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 18 citations in OpenAlex.
- Utility of the fast-field-echo resembling a computed tomography using restricted echo-spacing sequence in evaluating ossification of the posterior longitudinal ligament of the cervical spine.Quantitative imaging in medicine and surgery · 2026Article
- DREAMER: Rapid and Simultaneous Multiple Contrast Magnetic Resonance Imaging of Solid and Soft Tissue.Magnetic resonance in medicine · 2026Article
- Three contrasts in 3 min: Rapid, high-resolution, and bone-selective UTE MRI for craniofacial imaging with automated deep-learning skull segmentation.Magnetic resonance in medicine · 2025Article
- UTE MRI technical developments and applications in osteoporosis: a review.Frontiers in endocrinology · 2025Review
- Craniofacial Imaging of Pediatric Patients by Ultrashort Echo-Time Bone-Selective MRI in Comparison to CT.Academic radiology · 2024Article
- MR Cranial Bone Imaging: Evaluation of Both Motion-Corrected and Automated Deep Learning Pseudo-CT Estimated MR Images.AJNR. American journal of neuroradiology · 2024Article
- Cranial bone imaging using ultrashort echo-time bone-selective MRI as an alternative to gradient-echo based "black-bone" techniques.Magma (New York, N.Y.) · 2024Article
- Automatic Segmentation of Bone Selective MR Images for Visualization and Craniometry of the Cranial Vault.Academic radiology · 2022Article
- Complexity and data mining in dental research: A network medicine perspective on interceptive orthodontics.Orthodontics & craniofacial research · 2021Review
- Detection of Coalescent Acute Mastoiditis on MRI in Comparison with CT.Clinical neuroradiology · 2021Article
- Article
- Bone-Selective MRI as a Nonradiative Alternative to CT for Craniofacial Imaging.Academic radiology · 2020Article
- Self-Navigated Three-Dimensional Ultrashort Echo Time Technique for Motion-Corrected Skull MRI.IEEE transactions on medical imaging · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
Abstract
purposeTo develop a dual-radiofrequency (RF), dual-echo, 3D ultrashort echo-time (UTE) pulse sequence and bone-selective image reconstruction for rapid high-resolution craniofacial MRI.
methodsThe proposed pulse sequence builds on recently introduced dual-RF UTE imaging. While yielding enhanced bone specificity by exploiting high sensitivity of short T
resultsThe proposed technique achieves 1.1-mm isotropic skull imaging in 3 minutes without visual loss of image quality, compared to the parent technique (scan time = 12 minutes). Bone-specific images and corresponding 3D renderings of the skull were found to depict the expected craniofacial anatomy over the entire head.
conclusionThe proposed method is able to achieve high-resolution volumetric craniofacial images in a clinically practical imaging time, and thus may prove useful as a potential alternative to computed tomography.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.