Evidence map›Paper›PMID 30565104›Full record

ArticleObesity surgery2019

Stapler-Less Robotic Partial Gastrectomy: a Safety and Feasibility Experimental Study.

Tomasz Rogula, David Leifer, Jacob A Petrosky, Xiuli Liu, Michal Janik, Valerie Zeer, Piotr Fiedorczuk, Jan Baczek, Philip Schauer

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Obesity surgery, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.5field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 6 institutions in 2 countries.

Tomasz RogulaCase Western Reserve University, School of Medicine, 10900 Euclid Avenue, T402, Cleveland, OH, 44106-4924, USA. txr103@case.edu.ORCID 0000-0002-8719-6880
David LeiferCleveland Clinic, Cleveland, OH, USA.
Jacob A PetroskyCleveland Clinic, Cleveland, OH, USA.
Xiuli LiuUniversity of Florida, Gainesville, FL, USA.
Michal JanikDepartment of General, Oncologic, Metabolic and Thoracic Surgery, Military Institute of Medicine Warszawa, Warsaw, Poland.
Valerie ZeerCase Western Reserve University, School of Medicine, 10900 Euclid Avenue, T402, Cleveland, OH, 44106-4924, USA.
Piotr FiedorczukMedical University of Bialystok, Białystok, Poland.
Jan BaczekMedical University of Bialystok, Białystok, Poland.
Philip SchauerCleveland Clinic, Cleveland, OH, USA.
Cleveland Clinic · USMedical University of Białystok · PLJan Kochanowski University · PLUniversity of Florida · USUniversity School · USWojskowy Instytut Medycyny Lotniczej · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundNo true preliminary work has been performed and published on the use of the bipolar cautery devices for transection of the stomach when performed as a part of the sleeve gastrectomy or gastric wedge resection. The objective of this study was to investigate the feasibility and safety of substitution of linear surgical stapling devices for use of a bipolar electrosurgical sealing instrument in the performance of a totally robotic partial gastrectomy (TRPG).

methodsTen female pigs were assigned to an intervention or control group. Intervention included TRPG with a robotic bipolar tissue coagulation device. In the control group, TRPG was performed using the staplers. Assessed outcomes included presence of the intraoperative and postoperative bleeding or leak and features of the sections from the stapled line or sutured line.

resultsMean operating time was (130 ± 31 min) and (87 ± 23 min) in the study and control groups (p = 0.03). Intraoperative gastroscopy revealed slow bleeding associated with the staple line in 3/5 control pigs; oozing was not appreciated in any of the study pigs (0/5). No leak was detected during intraoperative gastroscopy. No major complications were suspected postoperatively or identified at postmortem exam in either group. Mean injury width was (1.12 ± 0.93 mm) in the control group with greater mean injury width (7.88 ± 3.73 mm) in the study group (p = 0.001). Mean depth of ulceration was (0.99 ± 0.94 mm) in the control group, with greater mean ulceration depth (2.25 ± 0.84 mm) in the study group (p = 0.002).

conclusionThe study showed the technical feasibility of performing stapler-less gastric wedge resection. The electrocautery alone failed to demonstrate the technical feasibility which was obtained with the concomitant use of a tissue clamp and a suture.

Indexed as

Robotic Surgical ProceduresAnimalsElectrocoagulationGastrectomyGastroscopyModels, AnimalOperative TimeSurgical StaplersSwineAnimal modelExperimental surgeryPartial gastrectomyStapler-less totally robotic sleeve gastrectomyWedge gastric resection

Identifiers

PMID30565104
OpenAlexW2903783213

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.