Evidence map›Paper›PMID 30558201›Full record

ArticleSensors (Basel, Switzerland)2018

Acetylcholinesterase Biosensor Based On Mesoporous Hollow Carbon Spheres/Core-Shell Magnetic Nanoparticles-Modified Electrode for the Detection of Organophosphorus Pesticides.

Ruiping Luo, Zijie Feng, Guannan Shen, Yi Xiu, Yukun Zhou, Xiaodi Niu, Hongsu Wang

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Review
  4. Review
  5. Review
  6. Review
  7. Review
  8. Article
  9. Article
  10. Review
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ruiping LuoCollege of Food Science and Engineering, Jilin University, Changchun 130062, China. luorp16@mails.jlu.edu.cn.
Zijie FengCollege of Food Science and Engineering, Jilin University, Changchun 130062, China. fengzj9916@mails.jlu.edu.cn.
Guannan ShenCollege of Food Science and Engineering, Jilin University, Changchun 130062, China. shenguannan@163.com.
Yi XiuCollege of Food Science and Engineering, Jilin University, Changchun 130062, China. xiuyi17@mails.jlu.edu.cn.
Yukun ZhouCollege of Food Science and Engineering, Jilin University, Changchun 130062, China. zhouyk9916@mails.jlu.edu.cn.
Xiaodi NiuCollege of Food Science and Engineering, Jilin University, Changchun 130062, China. niuxd@jlu.edu.cn.
Hongsu WangCollege of Food Science and Engineering, Jilin University, Changchun 130062, China. wanghs@jlu.edu.cn.ORCID 0000-0002-6696-9303

Funding

Interdisciplinary training program for young teachers and students in Jilin University 415010300033National Nature Science Foundation of China 31572566Training plan for young backbone teachers in Jilin University 419080500807
6 · The paper itself

Abstract

The present study investigated the synthesis of mesoporous hollow carbon spheres (MHCS) and magnetic mesoporous hollow carbon spheres with core-shell structures (Fe₃O₄@MHCS). Two acetylcholinesterase sensors (acetylcholinesterase/mesoporous hollow carbon spheres/glassy carbon electrode (AChE/MHCS/GCE) and acetylcholinesterase/core-shell magnetic mesoporous hollow carbon spheres/glassy carbon electrode (AChE/Fe₃O₄@MHCS/GCE) based on mesoporous carbon materials were prepared. Under the optimum conditions, using Malathion as the model compound, the developed biosensors showed a wide detection range, low detection limit, good reproducibility, and high stability. The AChE/MHCS/GCE electrochemical sensor response exhibited two good linear ranges at the incubation time of 10 min at the Malathion concentration ranges of 0.01 to 100 ppb and 100 to 600 ppb, with a detection limit of 0.0148 ppb (S/N = 3). The AChE/Fe₃O₄@MHCS/GCE electrochemical sensor that was operated with an incubation time of 12 min at the malathion concentration ranges between 0.01⁻50 ppb and 50⁻600 ppb had a detection limit of 0.0182 ppb (S/N = 3). Moreover, the AChE/MHCS/GCE and AChE/Fe₃O₄@MHCS/GCE biosensors were effective for the detection of real samples, and were demonstrated to be suitable for the field-testing of organophosphorus pesticide (OP) residues.

Indexed as

acetylcholinesterase (AChE)core-shell structureMalathionmesoporous hollow carbon spheres (MHCS)

Identifiers

PMID30558201
PMCPMC6308450

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.