Evidence map›Paper›PMID 30554181›Full record

ArticleJournal of neurosurgery2019

Intraoperative near-infrared imaging with receptor-specific versus passive delivery of fluorescent agents in pituitary adenomas.

Steve S Cho, Jun Jeon, Love Buch, Shayoni Nag, MacLean Nasrallah, Philip S Low, M Sean Grady, Sunil Singhal, John Y K Lee

Open access · greenAbstract readComparative Study
In one paragraph

Article in Journal of neurosurgery, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 30 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
30citing papers in PubMed, 1 pooled it
5.1field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

30 citing papers in PubMed, 1 synthesis or guideline pooled it, 46 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Article
  4. Translation of Intraoperative Molecular Imaging for Clinical Use.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2026
    Review
  5. Actionable Feedback on Signal-to-Background Ratios During Drop-in Radioguided Surgery.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2026
    Article
  6. Review
  7. Review
  8. Review
  9. Review
  10. Review
  11. Review
  12. Review
  13. Article
  14. Review
  15. Intraoperative Tumor Detection Using Pafolacianine.International journal of molecular sciences · 2022
    Review
  16. Review
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Steve S ChoDepartments of1Neurosurgery.
Jun JeonDepartments of1Neurosurgery.
Love BuchDepartments of1Neurosurgery.
Shayoni NagDepartments of1Neurosurgery.
MacLean Nasrallah2Pathology, and.
Philip S Low5Department of Biochemistry, Purdue University, West Lafayette, Indiana.
M Sean GradyDepartments of1Neurosurgery.
Sunil Singhal3Surgery, Hospital of the University of Pennsylvania.
John Y K LeeDepartments of1Neurosurgery.
Hospital of the University of Pennsylvania · USUniversity of Pennsylvania · USPurdue University West Lafayette · US

Funding

Institutional Clinical and Translational Science AwardUL1TR000003 · NCATS · UNIVERSITY OF PENNSYLVANIA · PI FITZGERALD, GARRET A · 2012 to 2015
$38.9M
Near infrared intraoperative molecular imaging of lung adenocarcinomaR01CA193556 · NCI · UNIVERSITY OF PENNSYLVANIA · PI LOW, PHILIP STEWART, SINGHAL, SUNIL · 2016 to 2020
$3.3M
NCATS NIH HHS UL1 TR000003NCI NIH HHS R01 CA193556
6 · The paper itself

Abstract

objectiveIntraoperative molecular imaging with tumor-targeted fluorescent dyes can enhance resection rates. In contrast to visible-light fluorophores (e.g., 5-aminolevulinic-acid), near-infrared (NIR) fluorophores have increased photon tissue penetration and less contamination from tissue autofluorescence. The second-window ICG (SWIG) technique relies on passive accumulation of indocyanine green (ICG) in neoplastic tissues. OTL38, conversely, targets folate receptor overexpression in nonfunctioning pituitary adenomas. In this study, we compare the properties of these 2 modalities for NIR imaging of pituitary adenomas to better understand the potential for NIR imaging in neurosurgery.

methodsA total of 39 patients with pituitary adenomas were enrolled between June 2015 and January 2018 in 2, sequential, IRB-approved studies. Sixteen patients received systemic ICG infusions 24 hours prior to surgery, and another 23 patients received OTL38 infusions 2-3 hours prior to surgery. NIR fluorescence signal-to-background ratio (SBR) was recorded during and after resection. Immunohistochemistry was performed on the 23 adenomas resected from patients who received OTL38 to assess expression of folate receptor-alpha (FRα).

resultsAll 16 adenomas operated on after ICG administration demonstrated strong NIR fluorescence (mean SBR 4.1 ± 0.69 [SD]). There was no statistically significant difference between the 9 functioning and 7 nonfunctioning adenomas (p = 0.9). After administration of OTL38, the mean SBR was 1.7 ± 0.47 for functioning adenomas, 2.6 ± 0.91 for all nonfunctioning adenomas, and 3.2 ± 0.53 for the subset of FRα-overexpressing adenomas. Tissue identification with white light alone for all adenomas demonstrated 88% sensitivity and 90% specificity. SWIG demonstrated 100% sensitivity but only 29% specificity for both functioning and nonfunctioning adenomas. OTL38 was 75% sensitive and 100% specific for all nonfunctioning adenomas, but when assessment was limited to the 9 FRα-overexpressing adenomas, the sensitivity and specificity of OTL38 were both 100%.

conclusionsIntraoperative imaging with NIR fluorophores demonstrates highly sensitive detection of pituitary adenomas. OTL38, a folate-receptor-targeted fluorophore, is highly specific for nonfunctioning adenomas but has no utility in functioning adenomas. SWIG, which relies on passive diffusion into neoplastic tissue, is applicable to both functioning and nonfunctioning pituitary adenomas, but it is less specific than targeted fluorophores. Thus, targeted and nontargeted NIR fluorophores play important, yet distinct, roles in intraoperative imaging. Selectively and intelligently using either agent has the potential to greatly improve resection rates and outcomes for patients with intracranial tumors.

Indexed as

AdenomaAdultAgedAminolevulinic AcidDrug Delivery SystemsFemaleFluorescent DyesFolate Receptors, GPI-AnchoredHumansIntraoperative Neurophysiological MonitoringMaleMiddle AgedPilot ProjectsPituitary NeoplasmsSpectroscopy, Near-InfraredAminolevulinic AcidFluorescent DyesFolate Receptors, GPI-Anchored5-ALA = 5-aminolevulinic acidACTH = adrenocorticotropic hormoneEPR = enhanced permeability and retentionfolate receptorFRα = folate receptor–alphaGH = growth hormoneICG = indocyanine greenindocyanine-greennear-infrared imagingNIR = near-infraredNPV = negative predictive valuepituitary adenomapituitary surgeryPPV = positive predictive valueSBR = signal-to-background ratioSPECT = single-photon emission computed tomographySWIG = second-window ICGtargeted imagingTSH = thyroid-stimulating hormone

Identifiers

PMID30554181
PMCPMC10985533
OpenAlexW2917667162

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.