Evidence map›Paper›PMID 30543705›Full record

ArticlePloS one2018

Optimization of PET reconstruction algorithm, SUV thresholding algorithm and PET acquisition time in clinical 11C-acetate PET/CT.

Sara Strandberg, Armin Hashemi, Jan Axelsson, Katrine Riklund

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 41% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Sara StrandbergDepartment of Radiation Sciences, Diagnostic Radiology, Umea University, Umea, Sweden.ORCID 0000-0002-0943-8178
Armin HashemiDepartment of Radiation Sciences, Diagnostic Radiology, Umea University, Umea, Sweden.
Jan AxelssonDepartment of Radiation Sciences, Diagnostic Radiology, Umea University, Umea, Sweden.
Katrine RiklundDepartment of Radiation Sciences, Diagnostic Radiology, Umea University, Umea, Sweden.
Umeå University · SE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introduction11C-acetate (ACE)-PET/CT is used for staging of high-risk prostate cancer. PET data is reconstructed with iterative algorithms, such as VUEPointHD ViP (VPHD) and VUEPoint HD Sharp IR (SharpIR), the latter with additional resolution recovery. It is expected that the resolution recovery algorithm should render more accurate maximum and mean standardized uptake values (SUVmax and SUVmean) and functional tumor volumes (FTV) than the ordinary OSEM. Performing quantitative analysis, choice of volume-of-interest delineation algorithm (SUV threshold) may influence FTV. Optimizing PET acquisition time is justified if image quality and quantitation do not deteriorate. The aim of this study is to identify the optimal reconstruction algorithm, SUV threshold and acquisition time for ACE-PET/CT.

methodsACE-PET/CT data acquired with a General Electric Discovery 690 PET/CT from 16 consecutive high-risk prostate cancer patients was reconstructed with VPHD and SharpIR. Forty pelvic lymph nodes (LNs) and 14 prostate glands were delineated with 42% and estimated threshold. SUVmax, SUVmean, FTV and total lesion uptake were measured. Default acquisition time was four minutes per bed position. In a subset of lesions, acquisition times of one, two and four minutes were evaluated. Structural tumor volumes (STV) of the LNs were measured with CT for correlation with functional volumetric parameters. To validate SUV quantification under different conditions with SharpIR 42%, recovery coefficients (RCs) of SUVmean and FTV were calculated from a phantom with 18F-fluoro-deoxy-glucose (FDG)-filled volumes 0.1-9.2cm3 and signal-to-background (S/B) ratios 4.3-15.9.

resultsWith SharpIR, SUVmax and SUVmean were higher and FTV lower compared with VPHD, regardless of threshold method, in both prostates and LNs. Total lesion uptake determined with both threshold methods was lower with SharpIR compared with VPHD with both threshold methods, except in subgroup analysis of prostate targets where estimated threshold returned higher values. Longer acquisition times returned higher FTV for both threshold methods, regardless of reconstruction algorithm. The FTV difference was most pronounced with one minute's acquisition per bed position, which also produced visually the highest noise. SUV parameters were unaffected by varying acquisition times. FTV with SharpIR 42% showed the best correspondence with STV. SharpIR 42% gave higher RCs of SUVmean and FTV with increasing phantom size and S/B-ratio, as expected.

conclusionsDelineation with SharpIR 42% seems to provide the most accurate combined information from SUVmax, SUVmean, FTV and total lesion uptake. Acquisition time may be shortened to two minutes per bed position with preserved image quality.

Indexed as

AlgorithmsCarbon RadioisotopesAcetatesAgedAged, 80 and overBiological TransportHumansImage Processing, Computer-AssistedLymph NodesMaleMiddle AgedPhantoms, ImagingPositron Emission Tomography Computed TomographyProstatic NeoplasmsRiskTime FactorsAcetatesCarbon-11Carbon Radioisotopes

Identifiers

PMID30543705
PMCPMC6292629
OpenAlexW2905106977

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.